Diagnosis and Treatment of Nonsurgical Sacroiliac Joint Pain - CAM 60123

Description
Sacroiliac joint (SIJ) arthrography using fluoroscopic guidance with an injection of an anesthetic has been explored as a diagnostic test for SIJ pain. Duplication of the patient’s pain pattern with the injection of contrast medium suggests a sacroiliac etiology, as does relief of chronic back pain with an injection of local anesthetic. Treatment of SIJ pain with corticosteroids, radiofrequency ablation (RFA), stabilization, or minimally invasive SIJ fusion has also been explored.

Background   
SACROILIAC JOINT PAIN
Similar to other structures in the spine, it is assumed the sacroiliac joint (SIJ) may be a source of low back pain. In fact, before 1928, the SIJ was thought to be the most common cause of sciatica. In 1928, the role of the intervertebral disc was elucidated, and from that point forward, the SIJ received less research attention.

Diagnosis
Research into SIJ pain has been plagued by a lack of a criterion standard to measure its prevalence and against which various clinical examinations can be validated. For example, SIJ pain typically presents without any consistent, demonstrable radiographic or laboratory features and most commonly exists in the setting of morphologically normal joints. Clinical tests for SIJ pain may include various movement tests, palpation to detect tenderness, and pain descriptions by the patient. Further confounding the study of the SIJ is that multiple structures, (e.g., posterior facet joints, lumbar discs) may refer pain to the area surrounding the SIJ.

Because of inconsistent information obtained from history and physical examination, some have proposed the use of image-guided anesthetic injection into the SIJ for the diagnosis of SIJ pain. Treatments being investigated for SIJ pain include prolotherapy (see evidence review 2.01.26), corticosteroid injection, radiofrequency ablation, stabilization, and arthrodesis. Some procedures have been referred to as SIJ fusion but may be more appropriately called fixation due to little to no bridging bone on radiographs. Devices for SIJ fixation/fusion that promote bone ingrowth to fixate the implants include a triangular implant (iFuse Implant System) and cylindrical threaded devices (e.g., Rialto, SImmetry, Silex, SambaScrew, SI-LOK). Some devices also have a slot in the middle where autologous or allogeneic bone can be inserted. This added bone is intended to promote the fusion of the SIJ.

A 2021 review identified 33 different devices that could be implanted using either a lateral transiliac approach (n = 21), posterior allograft approach (n = 6), posterolateral approach (n = 3), or a combination of the approaches (n = 3).1 The iliosacral and posterolateral approaches use up to 3 implants that pass through the ilium, while the posterior approach involves inserting implants directly into the SIJ. Many of the devices are intended to be used with allograft bone. Implants composed entirely of allograft bone are typically inserted through a posterior approach. The authors found no published evidence for 23 of the 33 devices identified.

Regulatory Status
A number of radiofrequency generators and probes have been cleared for marketing by the U.S. Food and Drug Administration (FDA) through the 510(k) process. In 2005, the SInergy® (Halyard; formerly Kimberly-Clark), a water-cooled single-use probe, was cleared by the FDA, listing the Baylis Pain Management Probe as a predicate device. The intended use is in conjunction with a radiofrequency generator to create radiofrequency lesions in nervous tissue.

FDA product codes: GXD, GXI.

Examples of types of commercially available SIJ fusion devices are listed in Table 1.

A number of percutaneous or minimally invasive fixation/fusion devices have been cleared for marketing by the FDA through the 510(k) process. FDA product codes: OUR.

Bone allograft products that are regulated as Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) for homologous use may be marketed specifically for use in SIJ fusion.

Table 1. Select Sacroiliac Fusion Devices

Device Manufacturer Features Graft Compatible Clearance   Date  
Lateral Transiliac Approach          
iFuse® SI Bone Titanium triangular rod with conventional manufacturing Y K110838 2011
iFuse® 3D SI Bone Titanium triangular 3D printed porous rod Y K162733 2017
FIREBIRD SI Fusion System™ Orthofix Cannulated screw Y K200696 2020
SambaScrew® Orthofix Cannulated screw Y K121148 2012
Silex Sacroiliac Joint Fusion® X-Spine Systems Cannulated screw Y K140079 2014
SI-LOK® Sacroiliac Joint Fixation System Globus Medical Cannulated screw Y K112028 2011
SImmetry® Sacroiliac Joint Fusion System RTI Cannulated screw Y K102907 2010
SIimpact® Sacroiliac Joint Fixation System Life Spine Cannulated screw Y K180749 2018
SIros™ Genesys Spine Cannulated screw Y K191748 2019
Triton SI Joint Fixation System™ Choice Spine 3D printed screw with porous graft windows Y K211449 2021
Posterolateral Approach          
Rialto™ SI Joint Fusion System Medtronic Cannulated screw Y K161210 2016
SacroFuse®/SIJFuse™ SpineFrontier Solid or hollow-cored screw Y K150017 2015
Posterior Approach          
Catamaran™ Tenon Medical Metal plug Y K180818 2018
CornerLoc™ Fusion Foundation
Solutions
Bone allograft N HCT/P N/A
LinQ™ SI Joint Stabilization PainTEQ Bone allograft N HCT/P N/A
NADIA™ SI Fusion System (DIANA) Ilion Medical Metal plug N K190580 2020
PsiF™ Posterior Sacroiliac Fusion Omnia Medical Bone allograft N HCT/P N/A
SIFix System® NuTech Bone allograft N HCT/P N/A
TransFasten™ Captiva Spine Bone allograft N HCT/P N/A

HCT/P: Human Cell and Tissue Product; N/A: not applicable; N: no; Y: yes.

Related Policies
20126 Prolotherapy
60125 Percutaneous Vertebroplasty and Sacroplasty
701116 Facet Joint Denervation
187 Sacroiliac Joint Fusion or Stabilization (archived 02/2021)

Policy
Arthrography of the sacroiliac joint is investigational and/or unproven and is therefore considered NOT MEDICALLY NECESSARY.

Injection of corticosteroid may be considered MEDICALLY NECESSARY for the treatment of SIJ pain when the following criteria have been met:

  • Pain has failed to respond to 3 months of conservative management, which may consist of therapies such as nonsteroidal anti-inflammatory medications, acetaminophen, manipulation, physical therapy, and a home exercise program.
  • The injection is performed under imaging guidance.
  • No more than 3 injections are to be given in 1 year.

Minimally invasive fixation/fusion of the SIJ using transiliac placement of a titanium triangular implant (e.g., iFuse) may be considered MEDICALLY NECESSARY when ALL of the following criteria have been met:

  • Pain is at least 5 on a 0 to 10 rating scale that impacts quality of life or limits activities of daily living.
  • There is an absence of generalized pain behavior (e.g., somatoform disorder) or generalized pain disorders (e.g., fibromyalgia).
  • Patients have undergone and failed a minimum 6 months of intensive nonoperative treatment that must include medication optimization, activity modification, bracing, and active therapeutic exercise targeted at the lumbar spine, pelvis, SIJ, and hip, including a home exercise program.
  • Pain is caudal to the lumbar spine (L5 vertebra), localized over the posterior SIJ, and consistent with SIJ pain.
  • A thorough physical examination demonstrates localized tenderness with palpation over the sacral sulcus (Fortin’s point) in the absence of tenderness of similar severity elsewhere.
  • There is a positive response to a cluster of 3 provocative tests (e.g., thigh thrust test, compression test, Gaenslen sign, distraction test, Patrick test, posterior provocation test).
  • Diagnostic imaging studies include ALL of the following:
    • Imaging (plain radiographs and computed tomography or magnetic resonance imaging) of the SIJ excludes the presence of destructive lesions (e.g., tumor, infection) or inflammatory arthropathy of the SIJ.
    • Imaging of the pelvis (anteroposterior plain radiograph) rules out concomitant hip pathology.
    • Imaging of the lumbar spine (computed tomography or magnetic resonance imaging) is performed to rule out neural compression or other degenerative condition that can be causing low back or buttock pain.
    • Imaging of the SIJ indicates evidence of injury and/or degeneration.
  • There is at least a 75% reduction in pain for the expected duration of the anesthetic used following an image-guided, contrast-enhanced intra-articular SIJ injection on 2 separate occasions.
  • A trial of a therapeutic SIJ injection (i.e., corticosteroid injection) has been performed at least once.

Fixation/fusion of the SIJ for the treatment of back pain presumed to originate from the SIJ is investigational/unproven therefore considered NOT MEDICALLY NECESSARY under all other conditions and with any other devices not listed above. 

The use of cooled radiofrequency denervation (Sinergy®) for a member with sacroiliac joint pain is considered medically necessary when the following conditions have been met:  

  1. Duration of sacroiliac joint pain is greater than 3 months.
  2. Physical signs and symptoms consistent with a diagnosis of sacroiliac joint pain syndrome are present which may include:
    1. Axial lower back, groin or buttock pain, or referred pain to the ipsilateral leg and foot or lower abdomen.
    2. Tenderness overlying the sacroiliac joint(s).
    3. Positive findings for any 3 or more of the following confirmatory clinical diagnostic tests for sacroiliac joint pain, such as:  

                                                          i.       Compression test (Approximation test).
                                                          ii.      Distraction test (Gapping test).
                                                          iii.     Gaenslen’s test (right and/or left).
                                                          iv.     Thigh thrust test (Ostergaard’s test).
                                                          v.      Sacral thrust. 

  1. Conservative treatment has been initiated, sustained and failed. Conservative treatment may be defined by any of the following:
    1. No clinically meaningful improvement from prescription drugs such as NSAIDS and/or muscle relaxants for 6 weeks after the start of the pain, or
    2. No clinically meaningful improvement from conservative self-care (muscle stretching, OTC medications, regular exercise) for 6 weeks after the start of the pain, or
    3. No clinically meaningful improvement from a prescribed and reasonably followed physical therapy core strengthening program (6 weeks) and
  2. Diagnostic sacroiliac joint injection or medial and lateral branch blocks to the sacroiliac joint have:
    1. Two diagnostic block procedures at the location of the planned ablation with documented 75% or greater pain relief as measured by the numerical rating scale (NRS) where “10” is the worst pain imaginable and “0” is no pain at all, within 7 days of the diagnostic block, or other equivalent pain scale, and
    2. A return to the pre-injection pain levels within 2 months of each diagnostic block, and
    3. Demonstrated pain relief is not attributable to the initiation of additional new physical or pharmacologic therapies, and
    4. The pain, signs and symptoms that led to the sacroiliac joint injection have returned in spite of adherence to supportive treatment such as structured exercise or therapy program, and
  3. The procedure is planned with fluoroscopic guidance. However, CT guidance may be used if fluoroscopy is not available in the patient’s geographic area OR the patient’s anatomy and circumstances make fluoroscopy ineffective for guidance.
  4. No more than 2 Cooled RF interventions per year are considered medically necessary. 

Radiofrequency ablation, other than cooled radiofrequency ablation, of the sacroiliac joint is investigational and/or unproven and is therefore considered NOT MEDICALLY NECESSARY

Policy Guidelines
This policy does not address the treatment of sacroiliac joint (SIJ) pain due to infection, trauma, or neoplasm.

This technically demanding procedure should only be done by surgeons who have specific training and expertise in minimally invasive SIJ fusion surgery for chronic SIJ pain and who regularly use image-guidance for implant placement.

Conservative nonsurgical therapy for the duration specified should include the following:

  • Use of prescription-strength analgesics for several weeks at a dose sufficient to induce a therapeutic response
    • Analgesics should include anti-inflammatory medications with or without adjunctive medications such as nerve membrane stabilizers or muscle relaxants.
  • Participation in at least 6 weeks of physical therapy (including active exercise) or documentation of why the individual could not tolerate physical therapy
  • Evaluation and appropriate management of associated cognitive, behavioral, or addiction issues
  • Documentation of individual compliance with the preceding criteria

A successful trial of controlled diagnostic lateral branch blocks consists of 2 separate positive blocks on different days with local anesthetic only (no steroids or other drugs), or a placebo-controlled series of blocks, under fluoroscopic guidance, that has resulted in a reduction in pain for the duration of the local anesthetic used (e.g., 3 hours longer with bupivacaine than lidocaine). There is no consensus on whether a minimum of 50% or 75% reduction in pain would be required to be considered a successful diagnostic block, although evidence supported a criterion standard of 75% to 100% reduction in pain with dual blocks. No therapeutic intra-articular injections (i.e., steroids, saline, other substances) should be administered for a period of at least 4 weeks before the diagnostic block. The diagnostic blocks should not be conducted under intravenous sedation unless specifically indicated (e.g., the individual is unable to cooperate with the procedure).

Coding
See the Codes table for details.

Rationale
Diagnosis of Sacroiliac Joint Pain
Evidence reviews assess whether a medical test is clinically useful. A useful test provides information to make a clinical management decision that improves the net health outcome. That is, the balance of benefits and harms is better when the test is used to manage the condition than when another test or no test is used to manage the condition.

The first step in assessing a medical test is to formulate the clinical context and purpose of the test. The test must be technically reliable, clinically valid, and clinically useful for that purpose. Evidence reviews assess the evidence on whether a test is clinically valid and clinically useful. Technical reliability is outside the scope of these reviews, and credible information on technical reliability is available from other sources.

The use of diagnostic blocks to evaluate sacroiliac joint (SIJ) pain builds on the use of diagnostic blocks to evaluate pain in other joints. Blinded studies with placebo controls, although difficult to conduct when dealing with invasive procedures, are ideally required for scientific validation of SIJ blocks, particularly when dealing with pain relief well-known to respond to placebo controls. In the typical evaluation of a diagnostic test, the results of the sacroiliac diagnostic block would then be compared with a criterion standard. However, no current criterion standard for SIJ disease exists. In fact, some have positioned SIJ injection as the criterion standard against which other diagnostic tests and physical exam may be measured.2 Ultimately, the point of diagnosis is to select patients appropriately for treatment that improves outcomes. Diagnostic tests that differentiate patients who do or do not benefit from a particular treatment are clinically useful.

Clinical Context and Test Purpose
The purpose of diagnostic SIJ block in patients who have suspected SIJ pain is to inform a decision whether to proceed to appropriate treatment.

The question addressed in this evidence review is: Does the use of a diagnostic SIJ block improve the net health outcome in patients who have suspected SIJ pain?

The following PICO was used to select literature to inform this review.

Populations
The relevant population of interest is individuals with suspected SIJ pain.

Interventions
The test being considered is a diagnostic SIJ block. Sacroiliac blocks are administered under imaging guidance using a local anesthetic.

Comparators
The following practice is currently being used to diagnose SIJ pain: standard of care, which can include physical provocative tests to induce pain and diagnostic imaging. SIJ pain confirmed with at least 3 physical provocative tests and ≥ 50% acute decrease in pain upon SIJ diagnostic block following failed conservative management reflect typical criteria.

Outcomes
The general outcomes of interest are an accurate diagnosis, reductions in pain and medication usage, improvement in functional outcomes (e.g., activities of daily living), improvement in the quality of life (QOL), and adverse events (AEs). A diagnostic result should be available within 1 to 2 hours postinjection.

Study Selection Criteria
For the evaluation of the clinical validity of a diagnostic SIJ block, studies that meet the following eligibility criteria were considered:

  • Reported on the accuracy of the marketed version of the technology (including any algorithms used to calculate scores)
  • Included a suitable reference standard (including a description of the reference standard)
  • Patient/sample clinical characteristics were described
  • Patient/sample selection criteria were described

Clinically Valid
A test must detect the presence or absence of a condition, the risk of developing a condition in the future, or treatment response (beneficial or adverse).

Systematic Reviews
Simopoulous et al. (2015) conducted a systematic review evaluating 11 diagnostic accuracy studies.3 Studies were heterogeneous in patient selection, SIJ block procedure, assessment, and pain relief cutoff thresholds for diagnosis confirmation, which ranged from 50% to 90% reduction in pain. Four studies utilizing single blocks assessed at a cutoff threshold of at least a 75% decrease in pain score were found to have variable SIJ pain prevalence estimates of 10% to 64%. Eight studies utilizing dual blocks assessed at a cutoff threshold of at least a 70% decrease in pain score were found to have variable SIJ pain prevalence estimates of 10% to 40.4% with corresponding false-positive rates of 22% to 26%. The evidence for dual blocks was graded Level II.

Manchikanti et al. (2013) updated an evidence review with guidelines on the diagnosis of SIJ pain for the American Society of Interventional Pain Physicians.4 Various studies evaluating diagnostic blocks were reviewed in which the criteria for a positive test varied from 50% to 100% relief from either single or dual blocks. The most stringent criterion (75% to 100% relief with dual blocks) was evaluated in 7 studies. The prevalence of a positive test in the 7 studies ranged from 10% to 44.4% in patients with suspected sacroiliac disease. The evidence for diagnostic sacroiliac intra-articular injections was considered to be good using 75% to 100% pain relief with single or dual blocks as the criterion standard.

Manchikanti et al. (2010) published 2 systematic reviews for interventional techniques for treatment and diagnosis of low back pain.5,6 Evidence for diagnostic sacroiliac injections was considered to be fair to poor, and no additional literature was identified since a systematic review by Rupert et al. (2009).7

Chou et al. (2009) conducted 2 systematic reviews at the Oregon Evidence-based Practice Center that informed practice guidelines from the American Pain Society.8,9 The systematic reviews concluded that no reliable evidence existed to evaluate the validity or utility of diagnostic SIJ block as a diagnostic procedure for low back pain with or without radiculopathy, with a resulting guideline recommendation of insufficient evidence. Data on SIJ steroid injection were limited to a small controlled trial, resulting in a recommendation of insufficient evidence for therapeutic injection of this joint.

Clinically Useful
A test is clinically useful if the use of the results informs management decisions that improve the net health outcome of care. The net health outcome can be improved if patients receive correct therapy, or more effective therapy, or avoid unnecessary therapy, or avoid unnecessary testing.

Direct Evidence
Direct evidence of clinical utility is provided by studies that have compared health outcomes for patients managed with and without the test. Because these are intervention studies, the preferred evidence would be from randomized controlled trials (RCTs).

Direct evidence supporting the clinical utility of using diagnostic SIJ blocks in this population were not identified.

Chain of Evidence
Indirect evidence on clinical utility rests on clinical validity. If the evidence is insufficient to demonstrate test performance, no inferences can be made about clinical utility.

Because the clinical validity of diagnostic SIJ blocks has not been established, a chain of evidence cannot be constructed.

Section Summary: Diagnosis of Sacroiliac Joint Pain
Findings from systematic reviews assessing the utility of diagnostic SIJ blocks are conflicting. In addition, there is no independent reference standard for the diagnosis of SIJ pain.

Treatment of Sacroiliac Joint Pain
Evidence reviews assess the clinical evidence to determine whether the use of a technology improves the net health outcome. Broadly defined, health outcomes are length of life, QOL, and ability to function including benefits and harms. Every clinical condition has specific outcomes that are important to patients and to managing the course of that condition. Validated outcome measures are necessary to ascertain whether a condition improves or worsens; and whether the magnitude of that change is clinically significant. The net health outcome is a balance of benefits and harms.

To assess whether the evidence is sufficient to draw conclusions about the net health outcome of a technology, 2 domains are examined: the relevance and the quality and credibility. To be relevant, studies must represent one or more intended clinical use of the technology in the intended population and compare an effective and appropriate alternative at a comparable intensity. For some conditions, the alternative will be supportive care or surveillance. The quality and credibility of the evidence depend on study design and conduct, minimizing bias and confounding that can generate incorrect findings. The RCT is preferred to assess efficacy; however, in some circumstances, nonrandomized studies may be adequate. Randomized controlled trials are rarely large enough or long enough to capture less common adverse events and long-term effects. Other types of studies can be used for these purposes and to assess generalizability to broader clinical populations and settings of clinical practice.

Treatment of Sacroiliac Joint Pain: Therapeutic Corticosteroid Injections
Clinical Context and Therapy Purpose

The purpose of therapeutic corticosteroid injections is to provide a treatment option that is an alternative to or an improvement on existing therapies in patients with SIJ pain.

The question addressed in this evidence review is: Does the use of therapeutic corticosteroid injections improve the net health outcome in individuals with SIJ pain?

The following PICO was used to select literature to inform this review.

Populations
The relevant population of interest is individuals with SIJ pain.

Interventions
The therapy being considered is a therapeutic corticosteroid injection.

Comparators
The following therapy is currently being used to treat SIJ: conservative management, including physical therapy.

Outcomes
The general outcomes of interest are symptoms (eg, reductions in pain), functional outcomes, QOL, reductions in medication use, and treatment-related morbidity. Follow-up at 3 to 15 months is of interest to monitor outcomes.

Study Selection Criteria
Methodologically credible studies were selected using the following principles:

  • To assess efficacy outcomes, comparative controlled prospective trials were sought, with a preference for RCTs.
  • In the absence of such trials, comparative observational studies were sought, with a preference for prospective studies.
  • To assess long-term outcomes and AEs, single-arm studies that capture longer periods of follow-up and/or larger populations were sought.
  • Studies with duplicative or overlapping populations were excluded.

Review of Evidence
Systematic Reviews

Hansen et al. (2012) published a systematic review of SIJ interventions.10 The primary outcomes were short-term (≤6 months) or long-term ( > 6 months) pain relief. Evidence quality was classified as good, fair, or limited/poor. Eleven studies (6 randomized, 5 nonrandomized trials) met the inclusion criteria. Reviewers found that evidence for intra-articular steroid injections was limited or poor, as was the evidence for periarticular injections (local anesthetic and steroid or botulinum toxin).

Randomized Controlled Trials
Tables 2 and 3 summarize the characteristics and results of select RCTs.

A trial by Visser et al. (2013) randomized 51 patients with SIJ and leg pain to physical therapy, manual therapy, or intra-articular injection of corticosteroid.11 Diagnosis of SIJ pain was based on provocation tests and not SIJ injections. In a blinded assessment, 25 (56%) patients were considered to be successfully treated at the 12-week follow-up visit based on complete relief of pain and improvement in the visual analog scale (VAS) score for pain.

Kim et al. (2010) reported a randomized, double-blind, controlled trial of intra-articular prolotherapy (see evidence review 20126) compared with steroid injection for SIJ pain.12 The trial included 48 patients with SIJ pain. Intra-articular dextrose water prolotherapy or steroid injections were administered under fluoroscopic guidance on a biweekly schedule, with a maximum of 3 injections. Injections were stopped when pain relief was 90% or greater, which required a mean of 2.7 prolotherapy injections and 1.5 steroid injections. Pain (numeric rating scale) and disability (Oswestry Disability Index [ODI]) scores were assessed at baseline, 2 weeks, and then monthly upon completing treatment. At the 2-week follow-up, pain and disability scores were significantly improved in both groups, with no significant difference between groups. The numeric rating scale pain score improved from 6.3 to 1.4 in the prolotherapy group and from 6.7 to 1.9 in the steroid group. At 6 months after treatment, 63.6% of patients in the prolotherapy group remained improved from baseline (≥ 50%), compared with 27.2% in the steroid group. At the 15-month follow-up, the cumulative incidence of sustained pain relief was 58.7% in the prolotherapy group compared with 10.2% in the steroid group. The median duration of the recurrence of severe SIJ pain was 3 months for the steroid group.

Table 2. Characteristics of Key RCTs Assessing Therapeutic Corticosteroid Injection

Study Countries Sites Dates Participants Interventions
          Active Comparator
Visser et al. (2013)11 NL 1 NR Diagnosed with SIJ pain and/or leg pain between 4 wk and 1 y in duration 18 patients randomized to IA injection 15 patients randomized to PT and 18 to manual therapy
Kim et al. (2010)12 Korea 1 NR Diagnosed with SIJ paina who failed additional 1-mo treatment 26 patients randomized to steroid; 26 analyzed 24 patients randomized to IA prolotherapy; 23 analyzed

IA: intra-articular; NL: The Netherlands; NR: not reported; PT: physical therapy; RCT: randomized controlled trial; SIJ: sacroiliac joint.
a Confirmed by ≥ 50% improvement in response to a single local anesthetic block.

Table 3. Results of Key RCTs Assessing Therapeutic Corticosteroid Injection

Study Pain Outcomes Functional Outcomes
Visser et al. (2013)11 VAS (SD) RAND-36 Physical Functioning1
Baseline 3 Months Baseline 3 Months
IA Corticosteroid Injection 5.7 (1.7) 5.0 (1.9) 45.3 (16.8) 37.9 (15.4)
Physical therapy 4.3 (1.2) 3.9 (1.4) 27.5 (6.5) 51.25 (28.7)
Manual therapy 5.2 (1.4) 3.3 (2.3) 30.0 (18.6) 60.5 (24.3)
Kim et al. (2010)12 NRS (SD) ODI (SD)
Baseline 2 Weeks Baseline 2 Weeks
Steroid 6.7 (1.0) 1.4 (1.1) 35.7 (20.4) 15.5 (10.7)
Prolotherapy 6.3 (1.1) 1.4 (1.1) 33.9 (15.5) 11.1 (10)

IA: intra-articular; NRS: Numerical Rating Scale; ODI: Oswestry Disability Index; RCT: randomized controlled trial; SD: standard deviation; VAS: Visual Analog Scale
1 Survey measures of health-related quality of life scored on a scale from 0 to 100, with 100 representing the highest level of functioning in a given category.

The purpose of the study relevance, conduct, and design limitations tables (see Tables 4 and 5) is to display notable limitations identified in each study. This information is synthesized as a summary of the body of evidence following each table and provides the conclusions on the sufficiency of the evidence supporting the position statement.

Table 4. Study Relevance Limitations

Study Populationa Interventionb Comparatorc Outcomesd Follow-Upe
Visser et al. (2013)11 4. Patients were recruited on the basis of SIJ-related leg pain with short duration of signs and symptoms. 2. Unclear which if any patients received a second injection.   4-5. Definition of successful treatment did not utilize standard pain relief threshold cutoff of at least 50%.  
Kim et al. (2010)12,        

SIJ: sacroiliac joint.
The study limitations stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.
a Population key: 1. Intended use population unclear; 2. Clinical context is unclear; 3. Study population is unclear; 4. Study population not representative of intended use.
b Intervention key: 1. Not clearly defined; 2. Version used unclear; 3. Delivery not similar intensity as comparator; 4.Not the intervention of interest.
c Comparator key: 1. Not clearly defined; 2. Not standard or optimal; 3. Delivery not similar intensity as intervention; 4. Not delivered effectively.
d Outcomes key: 1. Key health outcomes not addressed; 2. Physiologic measures, not validated surrogates; 3. No CONSORT reporting of harms; 4. Not establish and validated measurements; 5. Clinical significant difference not prespecified; 6. Clinical significant difference not supported.
e Follow-Up key: 1. Not sufficient duration for benefit; 2. Not sufficient duration for harms.

Table 5. Study Design and Conduct Limitations

Study Allocationa Blindingb Selective Reportingc Data Completenessd Powere Statisticalf
Visser et al. (2013)11 3. Allocation not described. 1. Trial was single-blinded 1. Not registered.   2. Power not calculated for primary outcome. 3. Confidence intervals and/or p values not reported.
Kim et al. (2010)12 3. Allocation not described.   1. Not registered.    

The study limitations stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.
a Allocation key: 1. Participants not randomly allocated; 2. Allocation not concealed; 3. Allocation concealment unclear; 4. Inadequate control for selection bias.
b Blinding key: 1. Not blinded to treatment assignment; 2. Not blinded outcome assessment; 3. Outcome assessed by treating physician.
c Selective Reporting key: 1. Not registered; 2. Evidence of selective reporting; 3. Evidence of selective publication.
d Data Completeness key: 1. High loss to follow-up or missing data; 2. Inadequate handling of missing data; 3. High number of crossovers; 4. Inadequate handling of crossovers; 5. Inappropriate exclusions; 6. No intent to treat analysis (per protocol for noninferiority trials).
e Power key: 1. Power calculations not reported; 2. Power not calculated for primary outcome; 3. Power not based on clinically important difference.
f Statistical key: 1. Intervention is not appropriate for outcome type: (a) continuous; (b) binary; (c) time to event; 2. Intervention is not appropriate for multiple observations per patient; 3. Confidence intervals and/or p values not reported; 4.Comparative treatment effects not calculated.

Case Series
Case series studies evaluating corticosteroid injections, described in systematic reviews, have shown variable findings at generally short-term follow-up.10,13

Section Summary: Therapeutic Corticosteroid Injections
Results from 2 small trials are insufficient to permit conclusions on the effect of this procedure on health outcomes. Steroid injections were not the most effective treatment in either trial and the degree of pain relief was limited. Larger trials with rigorous designs, preferably using sham injections, are needed to determine whether the treatment is effective.

Treatment of Sacroiliac Joint Pain: Radiofrequency Ablation
Clinical Context and Therapy Purpose

The purpose of radiofrequency ablation (RFA) is to provide a treatment option that is an alternative to or an improvement on existing therapies in patients with SIJ pain.

The question addressed in this evidence review is: Does the use of RFA improve the net health outcome in individuals with SIJ pain?

The following PICO was used to select literature to inform this review.

Populations
The relevant population of interest is individuals with SIJ pain.

Interventions
The therapy being considered is RFA, also known as radiofrequency neurotomy. RFA involves heating a portion of a pain-transmitting nerve to create a heat lesion. The goal of the heat lesion is to functionally denervate the SIJ and prevent the transmission of pain signals to the brain. Several variations of RFA are available, including water-cooled, pulsed, and conventional continuous RFA. Water-cooled RFA produces larger lesions than the other 2 modalities, however, lesion size is also dependent on temperature, needles size, and procedure duration. Lateral branch RFA targets the SIJ nerves.

Comparators
The following therapy is currently being used to treat SIJ pain: conservative therapy.

Outcomes
The general outcomes of interest are symptoms (e.g., reductions in pain), functional outcomes, QOL, reductions in medication use, and treatment-related morbidity. Follow-up at 3 and 15 months is of interest to monitor outcomes.

Study Selection Criteria
Methodologically credible studies were selected using the following principles:

  • To assess efficacy outcomes, comparative controlled prospective trials were sought, with a preference for RCTs.
  • In the absence of such trials, comparative observational studies were sought, with a preference for prospective studies.
  • To assess long-term outcomes and AEs, single-arm studies that capture longer periods of follow-up and/or larger populations were sought.
  • Studies with duplicative or overlapping populations were excluded.

Review of Evidence
Systematic Reviews

Tables 6 and 7 summarize the characteristics and results of select systematic reviews.

Chou et al. (2021) conducted a systematic review and meta-analysis on interventional treatments for acute and chronic pain for the Agency for Healthcare Research and Quality for use by the Centers for Medicare & Medicaid Services.14 The systematic review identified 2 trials (N = 79) on cooled RFA versus sham for SIJ pain with results at 3 months, and 1 trial (N = 28) on cooled RFA versus sham with results at 1 month. Meta-analysis indicated that cooled RFA is probably more effective for pain and function compared to sham at 1 and 3 months with moderate to large benefits. The strength of evidence was rated moderate for pain and function at 3 months and low for function at 1 month. When comparing cooled RFA to conventional RFA, 1 trial (N = 43) showed no differences at 1 or 3-month follow-up and a small, nonstatistically significant reduction in pain at 6 months. The strength of evidence was rated as low.

Chappel et al. (2020) performed a meta-analysis of RFA for chronic back pain.15 The review included 5 RCTs comparing RFA to sham or medical treatment in patients with chronic SIJ pain with follow-up from 1 to 3 months, and 1 study that had a follow-up to 12 months. This meta-analysis did not include pulsed RFA. Low-quality evidence indicated that RFA led to a modest reduction in pain at 1 to 3-month follow-up, but there was no significant reduction in pain in the single RCT (n = 228) that had 6- and 12-month follow-up.16 The RCT by Juch et al. (2017) with 12-month follow-up is described in greater detail below.

Chen et al. (2019) performed a meta-analysis of 5 RCTs comparing RFA to sham or medical treatment in patients with chronic SIJ pain.17, Various RFA procedures were represented, including percutaneous, cooled, and palisade SIJ radiofrequency neurotomy. Pain outcomes from all RCTs were pooled for the meta-analysis. Disability outcomes were only available for 2 studies utilizing cooled RFA. While studies showed no significant heterogeneity for disability outcomes, heterogeneity was high for pain outcomes.

Table 6. Characteristics of Systematic Reviews

Study Dates Trials Participants N (Range) Design Duration, mo
Chou et al. (2021)14 2007 – 2021 3 Patients with chronic SIJ pain treated by various RFA procedures compared to sham. 122 (28 to 51) RCTs 1 to 3
Chappel et al. (2020)15 2008 – 2019 5 Patients with chronic SIJ pain treated by various RFA procedures compared to sham or medical treatment. One trial with 12 mo follow-up had 228 participants. 384 RCTs 3 to 12
Chen et al. (2019)17 2012 – 2018 5 Patients with chronic SIJ pain treated by various RFA procedures compared to sham or medical treatment 311 (28 to 155) RCTs 3 to 6

SIJ: sacroiliac joint; RCT: randomized controlled trial; RFA: radiofrequency ablation.

Table 7. Results of Systematic Reviews

Study Pain Score Pain Score ODI Score GPE Score
Chou et al. (2021)14 3 mo vs sham RFA 6 mo vs conventional RFA    
Total N 79      
Cooled RFA -2.4 -3.8    
Sham or coventional RFA -0.8 -3.0    
p .04 .041    
Chappel et al. (2020)15 1 to 3 mo 6 mo    
Total N 5 studies1; n = 384 1 study1; n = 228    
MD (95% CI) -1.53 (-2.62 to 0.45) -0.28 (-1.00 to 0.44)    
p .02      
I2 (p) 83% NA    
Chen et al. (2019)17 Various RFA        
Total N 5 studies1; n = 311 See NRS Score1 2 studies; n = 79 1 study; n = 60
MD (95% CI) -2.13 (-3.4 to -0.87)   -8.91 (-16.44 to -1.38) 0.60 (-0.09 to 1.29)
p .001   .020 .090
I2 (p) 82.3% (NR)   44.8% (NR) NR

CI: confidence interval; GPE: Global Perceived Effect; MD: mean difference; NA: not applicable; NR: not reported; NRS: numerical rating scale; ODI: Oswestry Disability Index; RFA: radiofrequency ablation; VAS: visual analog score.
1 All pain scores (NRS, VAS) utilizing an 11-point scoring system were pooled together for the meta-analysis. 

Randomized Controlled Trials
Tables 8 and 9 summarize the characteristics and results of select RCTs.

Table 8. Characteristics of Key RCTs Assessing Radiofrequency Ablation

Study Countries Sites Dates Participants Interventions
          Active Comparator
Mehta et al. (2018)18 UK 1 2012 – 2015 Patients with SIJ pain confirmed by diagnostic intra-articular injection; only 17 of 30 enrolled patients were randomized due to results of interim analysis Multi-probe strip lesion RFA (n = 11) Sham (n = 6)
4 patients crossed over to active group after 3-month endpoint
Juch et al. (2017)16 Netherlands 16 2013 – 2014 Patients with chronic low back pain related to the SIJ RFA + exercise program (n = 116)
110 received RFA
81 received Palisade radiofrequency treatment
23 received cooled RFA
6 received multi-probe strip lesion RFA
Exercise program (n = 112)
69 completed program
18 did not complete program
25 with unknown completion
Van Tilburg et al. (2016)19 Netherlands NR 2012 – 2014 Patients with SIJ pain Percutaneous RFA to lateral branch and dorsal root primary ramus (n = 30) Sham (n = 30)
Zheng et al. (2014)20 China 1 2010 – 2012 Patients with ankylosing spondylitis and SIJ pain PSRN with computed tomography guidance (n = 82) Celecoxib treatment (n = 73)
Patel et al. (2012; 2016)21,22 U.S. NR 2008 – 2010 Patients with SIJ pain Lateral branch cooled RFA (n = 34) Sham (n = 17)

NR: not reported; PSRN: palisade sacroiliac joint radiofrequency neurotomy; RFA: radiofrequency ablation; RCT: randomized controlled trial: SIJ: sacroiliac joint.

Table 9. Results of Key RCTs Assessing Radiofrequency Ablation

Study Pain Outcomes Functional Outcomes Treatment Success
Mehta et al. (2018)18 NRS at Baseline (SD) NRS at Month 3 (SD) PCS1 at Baseline (SD) PCS at Month 3 (SD) Treatment Success
Strip lesion RFA 8.1 (0.8) 3.4 (2.0) 28.4 (7.1) 34.7 (10.8) NR
Sham 6.5 (2.0) 7.3 (0.8) 28.6 (5.0) 29.6 (5.6) NR
p Value NR < .001 NR 0.0645 NR
Juch et al. (2017)16 NRS at Month 3 (95% CI) NRS at Month 12 (95% CI) ODI at Month 3 (95% CI) ODI at Month 12 (95% CI) At Month 3, n/N (%) At Month 12, n/N (%)
RFA + exercise program 4.77 (4.31 to 5.24) 4.65 (4.16 to 5.13) 27.72 (24.50 to 30.95) 27.29 (23.89 to 30.69) 43/110 (39.10) 49/102 (48.03)
Exercise program 5.45 (4.94 to 5.95) 4.84 (4.30 to 5.38) 29.09 (25.47 to 2.71) 24.49 (20.74 to 28.23) 19/88 (21.59) 24/76 (31.78)
MD/RR (95% CI) -0.71 (-1.35 to -0.06) -0.07 (-0.74 to 0.60) -4.20 (-8.39 to -0.00) 2.11 (-2.25 to 6.47) 1.87 (1.13 to 2.71) 1.46 (0.92 to 2.02)
p Value .03 .83 .05 .34 .02 .10
Van Tilburg et al. (2016)19 Mean NRS at Baseline (SD) Mean NRS at Month 1 (SD) Mean GPE at Month 1 (SD) Mean GPE at Month 3 (SD) Treatment Success
Percutaneous RFA 7.2 (1.4) 5.4 (1.7) 3.2 (1.1) 3.4 (1.6) NR
Sham 7.5 (1.2) 5.4 (1.9) 3.3 (1.0) 3.4 (1.5) NR
P Value NR NR NR NR NR
Zheng et al. (2014)20 VAS at Week 12 (95% CI) VAS at Week 24 (95% CI) Mean BASFI2 at Baseline (95% CI) BASFI at Week 24 (95% CI) Treatment Success
PSRN 2.5 (2.2 to 3.0) 2.8 (2.5 to 3.2) 5.4 (5.0 to 5.8) 3.1 (2.7 to 3.6) NR
Celecoxib 4.4 (4.0 to 4.9) 5.0 (4.6 to 5.3) 5.3 (4.8 to 5.8) 5.0 (4.5 to 5.5) NR
MD (95% CI) -1.9 (-2.4 to -1.4) -2.2 (-2.6 to -1.6) NR -1.9 (-2.5 to -1.2) NR
p Value < .0001 < .0001 NR < .0001 NR
Patel et al. (2012; 2016)21,22 NRS at Baseline (SD) NRS at Month 3 (SD) ODI at Baseline (SD) ODI at Month 9 (SD) At Month 3, n/N (%) At Month 6, n/N (%)
Cooled RFA 6.1 (1.3) -2.4 (2.7) 37 (14) -11 (17) 16/34 (47) 13/34 (38)
Sham 5.8 (1.3) -0.8 (2.4) 35 (10) 2 (6) 2/17 (12) 7/16 (44)3
p Value .370 .035 .639 .011 .015 NR

BASFI: Bath Ankylosing Spondylitis Functional Index; CI; confidence interval; GPE: Global Perceived Effect; MD: mean difference; NR: not reported; NRS; Numeric Rating Scale; ODI: Oswestry Disability Index; PCS: Physical Component Score; RCT: randomized control trial; RFA: radiofrequency ablation; RR: relative risk; SD: standard deviation; VAS; Visual Analog Scale.
1 Higher scores on the SF-12 Physical Component Score (PCS) indicate improved outcomes.
2 The Bath Ankylosing Spondylitis Functional Index (BASFI) measures overall functional outcomes on a scale from 0 to 10 with 0 indicating best possible functioning.
3 Patients assigned to the sham group were allowed to crossover to active treatment after the 3-month study endpoint.

Mehta et al. (2018) published results from a double-blind, randomized, sham-controlled trial assessing the efficacy of radiofrequency neurotomy with a strip-lesioning device in patients with chronic SIJ pain.18 Seventeen of 30 enrolled patients were randomized to active (n = 11) or sham (n = 6) treatment. Recruitment was terminated after an interim analysis indicated a statistically significant difference in the pain outcome between groups. After the 3-month study endpoint, patients receiving sham treatment were allowed to crossover. While a statistically significant reduction in pain scores was reported at 3 months, there was no significant difference in functional outcome as measured by the Physical Component Score at 3 months. Due to the crossover design, it is difficult to gauge long-term outcomes and durability of the treatment.

Juch et al. (2017) reported a nonblinded multicenter RCT of radiofrequency denervation in 228 of 2,498 patients with suspected sacroiliac pain who were asked to participate in the trial.16 Patient selection criteria included body mass index (< 35 kg/m2), age (< 70 years old), and pain reduction of at least 50% within 30 to 90 minutes of receiving a diagnostic sacroiliac block (n = 228). An additional 202 patients had a negative diagnostic sacroiliac block; 1666 patients declined to participate in the trial. Patients meeting criteria were randomized to exercise plus radiofrequency denervation (n = 116) or an exercise program alone (n = 112) and were followed for a year. The RFA group had a modest improvement for the primary outcome at 3 months (-0.71; 95% confidence interval [CI]: -1.35 to -0.06), but the control group improved over time and there were no statistically significant differences between the groups for pain intensity score (p = .09) or in the number of patients who had more than a 30% reduction in pain intensity (p = .48) at 12 months. Limitations included the use of several techniques to achieve radiofrequency denervation, self-selection, lack of blinding, and a high dropout rate (31%) in the control group.

Van Tilburg et al. (2016) reported a sham-controlled randomized trial of percutaneous RFA in 60 patients with SIJ pain.19,Patients selected had clinically suspected SIJ pain and a decrease of 2 or more points on a 10-point pain scale with a diagnostic sacroiliac block. At 3-month follow-up, there was no statistically significant difference in pain level over time between groups (group by period interaction, p = .56). Both groups improved over time (≥ 2 points out of 10; p-value for time, p < .001). In their discussion, trialists mentioned the criteria and method used for diagnosing SIJ pain might have resulted in the selection of some patients without SIJ pain.

Zheng et al. (2014) reported on an RCT of palisade sacroiliac RFA in 155 patients with ankylosing spondylitis.20 Palisade RFA uses a row of radiofrequency cannulae perpendicular to the dorsal sacrum. Inclusion criteria were ages 18 to 75 years; diagnosis of ankylosing spondylitis; chronic low back pain for at least 3 months; axial pain below L5; no peripheral involvement; pain aggravation on manual pressing of the SIJ area; and at least 50% pain relief following fluoroscopically guided anesthetic injection into the joint. Patients who met the inclusion criteria were randomized to palisade RFA or celecoxib. Blinded evaluation to 24 weeks found that RFA (2.8) resulted in lower global VAS scores than celecoxib (5.0; p < .001) as well as improved scores for secondary outcome measures. This study lacked a sham control.

Patel et al. (2012) reported a randomized, double-blind, placebo-controlled trial of lateral branch neurotomy with a cooled radiofrequency probe.21 Twelve-month follow-up was reported in 2016.22 Fifty-one patients who had a positive response to 2 lateral branch blocks were randomized 2:1 to lateral branch radiofrequency or to sham. At a 3-month follow-up, significant improvements were observed in pain levels (-2.4 vs -0.8), physical function (14 vs 3), disability (-11 vs 2), and QOL (0.09 vs 0.02) for radiofrequency treatment compared with controls (all respectively). With treatment success defined as a 50% or greater reduction in numeric rating scale score, 47% of radiofrequency-treated patients and 12% of sham-treated patients achieved treatment success. The treatment response was durable to 12 months in the 25 of 34 patients who completed all follow-up visits22. Of the 9 patients who terminated study participation, 4 (12%) of 34 were considered treatment failures.

Tables 10 and 11 display notable relevance, design, and conduct limitations identified in each study.

Table 10. Study Relevance Limitations

Study Populationa Interventionb Comparatorc Outcomesd Follow-Upe
Mehta et al. (2019)18       1. Disability outcomes were not reported.  
Juch et al. (2017)16 4. Patients older than 70 years were excluded.   2. Not a sham control.    
Van Tilburg et al. (2016)19          
Zheng et al. (2014)20 1. Patients were required to have a diagnosis of ankylosing spondylitis in addition to chronic low back pain related to the SIJ.   2. Not a sham control.    
Patel et al. (2012)21,22        

SIJ: sacroiliac joint.
The study limitations stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.
a Population key: 1. Intended use population unclear; 2. Clinical context is unclear; 3. Study population is unclear; 4. Study population not representative of intended use.
b Intervention key: 1. Not clearly defined; 2. Version used unclear; 3. Delivery not similar intensity as comparator; 4. Not the intervention of interest.
c Comparator key: 1. Not clearly defined; 2. Not standard or optimal; 3. Delivery not similar intensity as intervention; 4. Not delivered effectively.
d Outcomes key: 1. Key health outcomes not addressed; 2. Physiologic measures, not validated surrogates; 3. No CONSORT reporting of harms; 4. Not established and validated measurements; 5. Clinical significant difference not prespecified; 6. Clinical significant difference not supported.
e Follow-Up key: 1. Not sufficient duration for benefit; 2. Not sufficient duration for harms.

Table 11. Study Design and Conduct Limitations

Study Allocationa Blindingb Selective Reportingc Data Completenessd Powere Statisticalf
Mehta et al. (2019)18       3. 66.6% of sham group patients crossed over to treatment group at 3 mo Other: Small study size due to interim analysis  
Juch et al. (2017)16   1-2. Study was not blinded.        
Van Tilburg et al. (2016)19       3. 63.3% of sham group patients crossed over to the treatment group    
Zheng et al. (2014)20            
Patel et al. (2012)21,22       3. Patients in the sham group could cross over at 3 mo  

The study limitations stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.
a Allocation key: 1. Participants not randomly allocated; 2. Allocation not concealed; 3. Allocation concealment unclear; 4. Inadequate control for selection bias.
b Blinding key: 1. Not blinded to treatment assignment; 2. Not blinded outcome assessment; 3. Outcome assessed by treating physician.
c Selective Reporting key: 1. Not registered; 2. Evidence of selective reporting; 3. Evidence of selective publication.
d Data Completeness key: 1. High loss to follow-up or missing data; 2. Inadequate handling of missing data; 3. High number of crossovers; 4. Inadequate handling of crossovers; 5. Inappropriate exclusions; 6. Not intent to treat analysis (per protocol for noninferiority trials).
e Power key: 1. Power calculations not reported; 2. Power not calculated for primary outcome; 3. Power not based on clinically important difference.
f Statistical key: 1. Intervention is not appropriate for outcome type: (a) continuous; (b) binary; (c) time to event; 2. Intervention is not appropriate for multiple observations per patient; 3. Confidence intervals and/or p values not reported; 4.Comparative treatment effects not calculated.

Section Summary: Radiofrequency Ablation
Meta-analysis of available sham-controlled RCTs suggests that there may be a small effect of RFA on SIJ pain at short-term (1 to 3 months) follow-up. However, the randomized trials of RFA have methodologic limitations, and there is limited data on the duration of the treatment effect. The single RCT with 6 and 12-month follow-up showed no significant benefit of RFA compared to an exercise control group at these time points. In addition, heterogeneity of RFA treatment techniques precludes generalizing results across different studies.

Treatment of Sacroiliac Joint Pain: Sacroiliac Joint Fusion/Fixation with a Transiliac Triangular Implant System
Clinical Context and Therapy Purpose

The purpose of SIJ fixation/fusion with a triangular implant is to provide a treatment option that is an alternative to or an improvement on existing therapies in patients with SIJ pain.

The question addressed in this evidence review is: Does the use of SIJ fixation/fusion with a triangular implant improve the net health outcome in individuals with SIJ pain?

The following PICO was used to select literature to inform this review.

Populations
The relevant population of interest is individuals with SIJ pain.

Interventions
The therapy being considered is SIJ fixation/fusion with a triangular implant.

Comparators
The following therapy is currently being used to treat SIJ pain: conservative therapy.

Outcomes
The general outcomes of interest are symptoms (e.g., reductions in pain), functional outcomes, QOL, reductions in medication use, and treatment-related morbidity. Follow-up from 1 to 5 years is of interest to monitor outcomes.

Study Selection Criteria
Methodologically credible studies were selected using the following principles:

  • To assess efficacy outcomes, comparative controlled prospective trials were sought, with a preference for RCTs.
  • In the absence of such trials, comparative observational studies were sought, with a preference for prospective studies.
  • To assess long-term outcomes and AEs, single-arm studies that capture longer periods of follow-up and/or larger populations were sought.
  • Studies with duplicative or overlapping populations were excluded.

Review of Evidence
Randomized Controlled Trials

Characteristics and results of RCTs are shown in Tables 12 to 14.

Investigation of Sacroiliac Fusion Treatment (INSITE)
Whang et al. (2015) reported an industry-sponsored nonblinded RCT, Investigation of Sacroiliac Fusion Treatment (INSITE) of the iFuse Implant System in 148 patients.23 The 12-month follow-up to this RCT was reported by Polly et al. (2015),24 and a 2-year follow-up was reported by Polly et al. (2016).25 However, by 12 months, almost all patients in the control group had crossed over to SIJ fusion, precluding a comparison between groups. Trial inclusion was based on a determination of the SIJ as a pain generator from a combination of a history of SIJ-localized pain, positive provocative testing on at least 3 of 5 established physical tests, and at least a 50% decrease in SIJ pain after image-guided local anesthetic injection into the SIJ. The duration of pain before enrollment averaged 6.4 years (range, 0.47 to 40.7 years). A large proportion of subjects (37%) had previously undergone lumbar fusion, SIJ steroid injections (86%), and RFA (16%).

Patients were randomized 2:1 to minimally invasive SIJ fusion (n = 102) or to nonsurgical management (n = 46). Nonsurgical management included a stepwise progression of nonsurgical treatments, depending on individual patient choice. During follow-up, control patients received physical therapy (97.8%), intra-articular steroid injections (73.9%), and RFA of sacral nerve roots (45.7%). The primary outcome measure was the 6-month success rate, defined as the proportion of treated subjects with a 20-mm improvement in SIJ pain in the absence of severe device-related or neurologic AEs or surgical revision. Patients in the control arm could crossover to surgery after 6 months. Baseline scores indicated that the patients were severely disabled, with VAS pain scores averaging 82.3 out of 100, and ODI scores averaging 61.9 out of 100 (0 = no disability, 100 = maximum disability).

At 6 months, success rates were 23.9% in the control group versus 81.4% in the surgical group (posterior probability of superiority > 0.999). A clinically important (≥ 15-point) improvement in ODI score was found in 27.3% of controls compared with 75.0% of fusion patients. Measures of QOL (36-Item Short-Form Health Survey, EuroQol-5D) also improved to a greater extent in the surgery group. Of the 44 nonsurgical management patients still participating at 6 months, 35 (79.5%) crossed over to fusion. Compared with baseline, opioid use at 6 months decreased from 67.6% to 58% in the surgery group and increased from 63% to 70.5% in the control group (p = .082). At 12 months, opioid use was similar between groups (55% vs 52%, p = .61).

Polly et al. (2016) reported 2-year outcomes from the SIJ fusion arm of this RCT.25, Of 102 subjects originally assigned to SIJ fusion and treated, 89 (87%) were evaluated at 2 years. In this report, clinical outcomes were based on the amount of improvement in SIJ pain and in ODI scores. The improvement was defined as a change of 20 points in the SIJ pain score and 15 points in the ODI score. Substantial improvement was defined as a change of 25 points in SIJ pain score-or an SIJ pain score of 35 or less-and an improvement of 18.8 points in the ODI score. At 24 months, 83.1% had improvements in SIJ pain score, and 68.2% had improvements in ODI scores. By 24 months, the proportion taking opioids was reduced from 68.6% at baseline to 48.3%.

Three-year follow-up results of the INSITE and Sacroiliac Joint Fusion with iFuse Implant System (SiFi) trials were published by Darr et al. (2018).26 Of 103 patients with SIJ dysfunction who were treated with minimally invasive SIJ fusion with triangular titanium implants, 60 (72.3%) patients reported an improvement in ODI scores of ≥ 15 points from baseline to 3 years. The mean ODI score decreased from 56 to 28 for the same time frame, an improvement of 28 points (p < .001); similarly, the mean SIJ pain score decreased to 26.2, reflecting a decrease of 55 points (p < .001). Over 3 years of follow-up, 168 AEs were reported in 75 patients, although only 22 of these events involved the pelvis. The study was limited by its lack of long-term data from a control group not receiving surgical treatment.

iFuse Implant System Minimally Invasive Arthrodesis (iMIA)
In 2016 and 2017, the iFuse Implant System Minimally Invasive Arthrodesis (iMIA) study group reported another industry-sponsored multicenter RCT of the iFuse Implant System in 103 patients.27,28 Selection criteria were similar to those of the trial by Whang et al. (2015), including at least a 50% pain reduction on SIJ block. The mean pain duration was 4.5 years, and about half of the patients were not working due to lower back pain. Additionally, 33% of patients had undergone prior lumbar fusion. Nonsurgical management included physical therapy and exercises at least twice per week; interventional procedures (e.g., steroid injections, RFA) were not allowed. The primary outcome was change in the VAS pain score at 6 months.

All patients assigned to iFuse underwent the procedure, and follow-up at 6 months was available for 49 of 51 patients in the control group and for all 52 patients in the iFuse group. Six-month results as reported by Sturesson et al. (2016) are shown in Table 12.27, At 6 months, VAS pain scores improved by 43.3 points in the iFuse group and by 5.7 points in the control group (p < .001). ODI scores improved by 25.5 points in the iFuse group and by 5.8 points in the control group (p < .001, between groups). An improvement in lower back pain by at least 20 VAS points (a minimal clinically important difference) was achieved in 78.8% of the SIJ fusion group versus 22.4% of controls (p<0.001). Quality of life outcomes showed a greater improvement in the iFuse group than in the control group. Changes in pain medication use were not reported. Patients in the conservative management group were allowed to cross over to SIJ fusion at 6 months.

Twelve and 24-month results from the iMIA trial were reported by Dengler et al. (2017, 2019).29,30 Twenty-one patients in the conservative management group had little or no improvement in symptoms and crossed over to SIJ fusion after the 6-month visit. These were analyzed with the last observation prior to crossover carried forward. At 12 months, low back pain had improved by 42 points (standard deviation [SD], 27.0) on a 100-point VAS in the SIJ fusion group compared with 14 points (SD = 33.4) in the conservative management group (p < .001). At 24 months back pain had improved by 45 points compared to 11 points in the control group, with 79% (37 of 47) of SIJ fusion patients achieving at least a 20 point improvement compared to 24% (11 of 46) of controls. At 24 months there was an improvement of 26 points in ODI compared to 8 points in controls (p < .001). Improvement of at least 20 points was observed in 64% of the SIJ fusion group compared to 24% of the conservative management group.

Table 12. Summary of Key RCT Characteristics

Study; Trial Countries Sites Dates Participants Interventions
          Active Comparator
Whang et al. (2015)23; INSITE U.S. 19 2013 – 2014 Patients 21 to 70 y with confirmed diagnosis of unilateral or bilateral SIJ dysfunction due to degenerative sacroiliitis and/or SIJ disruption 102 randomized to SIJ fusion 46 randomized to nonsurgical management
Sturesson et al. (2017)27; iMIA EU (Belgium, Germany, Italy, Sweden) 9 2013 – 2015 Patients 21 to 70 y with LBP for > 6 mo and diagnosed with SIJ as primary pain generatora 52 randomized to SIJ fusion 51 randomized to conservative management

iMIA: iFuse Implant System Minimally Invasive Arthrodesis; INSITE: Investigation of Sacroiliac Fusion Treatment; LBP: low back pain; RCT: randomized controlled trial; SIJ: sacroiliac joint.
a The 3 criteria for diagnosis of SIJ pain were as follows: pain was present or near the posterior superior iliac spine; there were at least 3 positive findings on 5 provocative tests; at least a 50% pain reduction on fluoroscopically guided injection of local anesthetic into the joint.

Table 13. Summary of Six-Month iFuse Results From INSITE and iMIA

Results VAS Score Success End Point ODI Score SF-36 PCS Score EQ-5D TTO Index
  Ctl iFuse Ctl iFuse Ctl iFuse Ctl iFuse Ctl iFuse
INSITE23                  
Baseline 82.2 82.3     61.1 62.2 30.8 30.2 0.47 0.44
Follow-up 70.4 29.8 23.9% 81.4%a 56.4 31.9 32.0 42.8 0.52 0.72
Change -12.1 -52.6a     -4.9 -30.3a 1.2 12.7 0.05 0.29
iMIA27                  
Baseline 73.0 77.7                
Follow-up 67.8 34.4                
Change -5.7 -43.3     -5.8 -25.5     0.11 0.37

Adapted from Whang et al. (2015)23 and Sturesson et al. (2015).27
The success endpoint was defined as a reduction in VAS pain score of ≥ 20, absence of device-related events, absence of neurologic worsening, and absence of surgical intervention.
Ctl: control; EQ-5D TTO Index: EuroQoL Time Tradeoff Index; iMIA: iFuse Implant System Minimally Invasive Arthrodesis; INSITE: Investigation of Sacroiliac Fusion Treatment; ODI: Oswestry Disability Index; SF-36 PCS: 36-Item Short-Form Health Survey Physical Component Summary; VAS: visual analog scale.
a p < .001.

Table 14. Extended Follow-Up From the INSITE and iMIA Trials

Outcome Measures Baseline (SD) 6 Months (SD) 12 Months (SD) 24 Months (SD)
INSITE23        
SIJ fusion pain score 82.3 29.8   26.7
Percent ≥ 20-point improvement pain       83.1%
SIJ fusion ODI score 57.2 31.9   28.7
% ≥ 15-point improvement ODI       68.2%
iMIA27,29,30       Mean Improvement (95% CI)
Back pain        
Conservative management 73.0 (13.8) 67.8 (20.3) 58.9 (28.2) 11.0
SIJ fusion 77.7 (11.3) 34.4 (23.9) 35.2 (25.5) 45.3 (37 to 54)
Leg pain        
Conservative management 47.1 (31.1) 46.5 (31.4) 41.7 (32.4) 7.7
SIJ fusion 52.7 (31.5) 22.6 (25.1) 24.0 (27.8) 32.0
ODI        
Conservative management 55.6 (13.7) 50.2 (17.2) 46.9 (20.8) 8 (2 to 14)
SIJ fusion 57.5 (14.4) 32.0 (18.4) 32.1 (19.9) 26 (21 to 32)

Adapted from Dengler et al. (2017).29
CI: confidence interval; iMIA: iFuse Implant System Minimally Invasive Arthrodesis; INSITE: Investigation of Sacroiliac Fusion Treatment; ODI: Oswestry Disability Index; SD: standard deviation; SIJ: sacroiliac joint.

Tables 15 and 16 display notable limitations identified in each study.

Table 15. Study Relevance Limitations

Study; Trial Populationa Interventionb Comparatorc Outcomesd Follow-Upe
Whang et al. (2015)23; INSITE          
Sturesson et al. (2017)27; iMIA 1. Patients with other contributory sources of LBP might have been enrolled with SIJ-caused LBP patients      

iMIA: iFuse Implant System Minimally Invasive Arthrodesis; INSITE: Investigation of Sacroiliac Fusion Treatment; LBP: low back pain; SIJ: sacroiliac joint.
The study limitations stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.

a Population key: 1. Intended use population unclear; 2. Clinical context is unclear; 3. Study population is unclear; 4. Study population not representative of intended use.
b Intervention key: 1. Not clearly defined; 2. Version used unclear; 3. Delivery not similar intensity as comparator; 4.Not the intervention of interest.
c Comparator key: 1. Not clearly defined; 2. Not standard or optimal; 3. Delivery not similar intensity as intervention; 4. Not delivered effectively.
d Outcomes key: 1. Key health outcomes not addressed; 2. Physiologic measures, not validated surrogates; 3. No CONSORT reporting of harms; 4. Not establish and validated measurements; 5. Clinical significant difference not prespecified; 6. Clinical significant difference not supported.
e Follow-Up key: 1. Not sufficient duration for benefit; 2. Not sufficient duration for harms.

Table 16. Study Design and Conduct Limitations

Study; Trial Allocationa Blindingb Selective Reportingc Data Completenessd Powere Statisticalf
Whang et al. (2015)23; INSITE            
Sturesson et al. (2017)27; iMIA   1. Intervention was nonblinded      

MIA: iFuse Implant System Minimally Invasive Arthrodesis; INSITE: Investigation of Sacroiliac Fusion Treatment.
The study limitations stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.
a Allocation key: 1. Participants not randomly allocated; 2. Allocation not concealed; 3. Allocation concealment unclear; 4. Inadequate control for selection bias.
b Blinding key: 1. Not blinded to treatment assignment; 2. Not blinded outcome assessment; 3. Outcome assessed by treating physician.
c Selective Reporting key: 1. Not registered; 2. Evidence of selective reporting; 3. Evidence of selective publication.
d Data Completeness key: 1. High loss to follow-up or missing data; 2. Inadequate handling of missing data; 3. High number of crossovers; 4. Inadequate handling of crossovers; 5. Inappropriate exclusions; 6. Not intent to treat analysis (per protocol for noninferiority trials).
e Power key: 1. Power calculations not reported; 2. Power not calculated for primary outcome; 3. Power not based on clinically important difference.
f Statistical key: 1. Intervention is not appropriate for outcome type: (a) continuous; (b) binary; (c) time to event; 2. Intervention is not appropriate for multiple observations per patient; 3. Confidence intervals and/or p values not reported; 4.Comparative treatment effects not calculated.

Nonrandomized Studies
Prospective cohort studies with good follow-up rates are more likely to provide valid estimates of outcomes. Principal results of the studies at 2- to 5-year follow-up are shown in Table 17.

Results from a cohort of 172 patients undergoing SIJ fusion reported to 2 years were published by Duhon et al. (2016).31,32 Patients were formally enrolled in a single-arm trial (SIFI NCT01640353) with planned follow-up for 24 months. Success was defined as a reduction of pain score of 20-mm on a 100-mm VAS, absence of device-related AEs, absence of neurologic worsening, and absence of surgical reintervention. Enrolled patients had a mean VAS pain score of 79.8, a mean ODI score of 55.2, and a mean pain duration of 5.1 years. At 6 months, 136 (80.5%) of 169 patients met the success endpoint, which met the prespecified Bayesian probability of success rate. Mean VAS pain scores were 30.0 at 6 months and 30.4 at 12 months. Mean ODI scores were 32.5 at 6 months and 31.4 at 12 months. At 2 years, 149 (87%) of 172 patients were available for follow-up. The VAS pain score at 2 years was 26.0, and the ODI score was 30.9. Thus, 1-year outcomes were maintained at 2 years. Other outcomes (e.g., QOL scores) showed similar maintenance or slight improvement compared with 1-year outcomes. Use of opioid analgesics decreased from 76.2% at baseline to 55% at 2 years. Over the 2 year follow-up, 8 (4.7%) patients required revision surgery.

Table 17. Two- to Five-Year Outcomes of the iFuse Implant

Studies and Outcomes Mean Baseline Value Mean 2- to 3-Year Value Difference or % Achieving Outcome 3 4 5 P
Duhon et al. (2016)31,32 SIFI              
N 172 149 (86.6%)          
Pain score (range, 0 to 100) 79.8 26.0 53.3        
Oswestry Disability Index score 55.2 30.9 24.5        
SF-36 score 31.7 40.7 8.9        
EQ-5D TTO score 0.43 0.71 0.27        
Whang et al. (2019)33 LOIS              
N 103         93  
VAS (range, 0 to 100) 81.5 (SD 12.7)         27.1 (29.4) <.001
Oswestry Disability Index score 56.3         29.9 (21.2) <.001
EQ-5D TTO score 0.45 (0.17)         0.75 (0.22) <.001
Opiod use 76.7% 53.9%   47.4% 42.6% 41.3%  
Not working due to back pain 16.5%         15.1%

All differences between baseline and 2- to 3-year values were statistically significant.
EQ-5D TTO Index: EuroQoL Time Tradeoff Index; INSITE: Investigation of Sacroiliac Fusion Treatment.; LOIS: Long Term Outcomes from INSITE and SIFI; SD: standard deviation; SF-36: 36-Item Short-Form Health Survey; SiFi: Sacroiliac Joint Fusion with iFuse Implant System; VAS: visual analog score.

In general, cohort studies and case series have shown improvements in VAS pain scores and other outcomes measures consistent in magnitude to the RCTs. The Long Term Outcomes from INSITE and SIFI (LOIS) trial was a prospective single-arm study that enrolled patients who had participated in 2 of the studies described above for evaluation at 3, 4, and 5 years.33 The primary success outcome, a reduction in VAS of ≥ 20 points in the absence of a serious device-related AE, neurologic worsening, or surgical revision, was obtained in 81.7% (95% CI: 72.4% to 89.0%) of patients at 5 years. The improvements in other clinical outcomes were maintained out to 5 years (Table 17 ). Opiod use decreased over time, although the contribution of the opioid use agreement cannot be determined. Fifteen percent of patients were not working due to back pain. Radiolucencies suggesting implant failure were observed in 5% of cases and were associated with incorrect placement. Bridging bone was observed in 45% of sides at 12 months, 71% at 24 months, and 88% at 60 months.

The Study of Bone Growth in the Sacroiliac Joint after Minimally Invasive Surgery with Titanium Implants (SALLY) is a 5-year multicenter study that will assess non-inferiority of outcomes with a 3-dimensional (3D) printed triangular implant as compared to the traditionally manufactured titanium coated implant. Twelve-month follow-up has been published for 46 of the 51 patients enrolled in the prospective cohort.34 The 6-month change in ODI met the non-inferiority margin, and secondary outcomes of pain, disability, and QOL were similar to those obtained in the INSITE, iMIA, and SIFI trials. Independent radiographic analysis showed bridging bone in 70% and 77% of sides imaged at 6 and 12 months, respectively, compared to 45% bridging bone in prior studies with the solid titanium coated implants. No breakage, migration, or subsidence was detected. However, there was no evidence that the increase in bridging bone led to an improvement in pain or functional outcomes compared to the milled implant at 12 months. Follow-up at 24 months was available for 84% of patients, with the stability of subjective and objective outcomes and similar efficacy for the 3D-printed implant and the milled implant from the earlier trials.34 Two patients had AEs related to the procedure and 2 had undergone revision. Follow-up is continuing.

Improved health outcomes are also supported by retrospective studies that compare SIJ fusion/fixation using a triangular implant with other treatments for SIJ pain.35,36 These results are consistent with the medium-term durability of the treatment. Analysis of an insurance database reported an overall incidence of complications to be 16.4% at 6 months and the cumulative revision rate at 4 years of 3.54%.37 Spain and Holt (2017) reported a retrospective review of surgical revision rates following SIJ fixation with either surgical screws or the iFuse triangular implant.36 Revision rates were lower with the iFuse device than observed with surgical screws.

Section Summary: Sacroiliac Joint Fusion/Fixation With a Transiliac Triangular Implant
The evidence on SIJ fusion/fixation with a triangular implant includes 2 nonblinded RCTs of minimally invasive fusion, prospective cohorts with more than 85% follow-up, and a case series. Both RCTs have reported outcomes past 6 months, after which crossover was allowed. Both studies reported significantly greater reductions in VAS pain scores and ODI scores in SIJ fusion patients than in control groups. The reductions in pain and disability observed in the SIJ fusion group at 6 months were maintained out to 1 year compared with controls who had not crossed over. The RCTs were nonblinded without a placebo or an active control group. In addition, pain has a significant subjective and psychological component, and cognitive-behavioral techniques to address pain were specifically excluded from the types of treatment that control subjects could obtain. As it relates to trial design, an independent assessment of pain outcomes would have been preferable. Prospective cohorts and case series with sample sizes ranging from 45 to 149 patients and low dropout rates (< 15%) also showed reductions in pain and disability that persist out to 5 years. The cohort studies and case series are consistent with the durability of treatment benefits.

Treatment of Sacroiliac Joint Pain: Sacroiliac Joint Fixation/Fusion With an Implant Other Than a Transiliac Triangular Implant
Clinical Context and Therapy Purpose

The purpose of SIJ fixation/fusion with a SIJ implant is to provide a treatment option that is an alternative to or an improvement on existing therapies in patients with SIJ pain.

The question addressed in this evidence review is: Does the use of SIJ fixation/fusion with an implant other than a transiliac triangular implant improve the net health outcome in individuals with SIJ pain?

The following PICO was used to select literature to inform this review.

Populations
The relevant population of interest is individuals with SIJ pain.

Interventions
The therapy being considered is SIJ fixation/fusion with an implant other than a transiliac triangular implant.

Numerous cannulated screws are marketed that use iliosacral and posterolateral approaches that pass through the ilium. Up to 3 implants may be used.

The posterior approach involves inserting implants into the ligamentous recess between the sacrum and ilium. The devices are intended to be used with allograft bone or are composed entirely of allograft bone. The posterior approach may be called distraction arthrodesis as the implants increase the joint space and create tension on the ligaments, repositioning the joint surfaces.

Comparators
The following therapy is currently being used to treat SIJ pain: conservative therapy.

Outcomes
The general outcomes of interest are symptoms (e.g., reductions in pain), functional outcomes, QOL, reductions in medication use, and treatment-related morbidity. Follow-up from 1 to 5 years is of interest to monitor outcomes.

Study Selection Criteria
Methodologically credible studies were selected using the following principles:

  • To assess efficacy outcomes, comparative controlled prospective trials were sought, with a preference for RCTs.
  • In the absence of such trials, comparative observational studies were sought, with a preference for prospective studies.
  • To assess long-term outcomes and AEs, single-arm studies that capture longer periods of follow-up and/or larger populations were sought.
  • Studies with duplicative or overlapping populations were excluded.

Review of Evidence
Systematic Reviews

Tran et al. (2019) published a systematic review comparing the effectiveness of minimally invasive joint fusion with a triangular implant (i.e., utilizing the iFuse device) compared to screw-type surgeries.38 A total of 20 studies were pooled to calculate a standardized mean difference across pain, disability, and global/QOL outcomes, including 14 studies evaluating the iFuse system and 7 studies evaluating cylindrical, threaded implants. Studies evaluating cylindrical, threaded implants consisted of case series and cohort studies. Patients receiving these implants experienced significantly worse pain outcomes (p = .03) compared to patients receiving iFuse, with a standardized mean difference of 1.28 (95% CI: 0.47 to 2.09) and 2.04 (95% CI: 1.76 to 2.33), respectively. A statistically significant difference in disability scores was reported between screw-type and iFuse implant groups (0.26 [95% CI: -1.90 to 2.41] vs 1.68 [95% CI: 1.43 to 1.94]; p = .01), with improved outcomes in the iFuse population. For global/QOL outcomes, a statistically significant difference in scores was reported between screw-type and iFuse implants groups (0.60 [95% CI: 0.33 to 0.88] vs 0.99 [95% CI: 0.75 to 1.24]; p = .04), with improved outcomes in the iFuse population.

A qualitative systematic review by Lorio et al. (2020) for the International Society for the Advancement of Spine Surgery found evidence on the safety and effectiveness of distraction (posterior) SIJ fusion was limited to 1 prospective multicenter study (described below), no comparative studies, and a small number of case series.39

Prospective Cohort Studies
Rappoport et al. (2017) reported an industry-sponsored prospective study of SIJ fusion with a cylindrical threaded implant (SI-LOK).40 The study included 32 patients using a diagnosis of SIJ dysfunction who had failed nonoperative treatment, including medication, physical therapy, and therapeutic injections. A diagnostic injection was performed to confirm the source of pain to the SIJ. The procedure included drilling to prepare for screw insertion and implantation of 3 screws, at least 1 of which was slotted. The slotted screws were packed with an autogenous bone graft from the drill reamings. Pain and disability scores were reduced following device implantation (see Table 18), and revisions within the first 12 months of the study were low (n = 2). At the 2 year follow-up, VAS scores remained low, although 4 (12.5%) did not return for follow-up and 2 patients required revision surgery; analysis did not count these as treatment failures.41

Araghi et al. (2017) published interim results from an industry-sponsored prospective cohort study evaluating pain and ODI outcomes for patients treated for SIJ pain with the SImmetry system.42 For the 50 patients enrolled at the time of publication, the mean VAS score had decreased from 76.2 at baseline to 35.1 at 6 months after the procedure (p < .001), with 36 (72%) patients achieving minimal clinically important difference (≥ 20-point reduction). The mean ODI score likewise showed significant improvement from baseline to 6 months, decreasing from 55.5 to 35.3 (p < .001). Over half of the cohort (56% [n = 28]) achieved the minimal clinically important difference (15-point reduction) on the ODI. Prior to surgery, 66% (n = 33) of the cohort were on opioids, decreasing to 30% (n = 15) at the 6-month follow-up (p < .001). QOL was assessed with the EQ-5D time trade-off index: at baseline, the mean EQ-5D was 0.51, decreasing to 0.69 after 6 months (p < .001). Likewise, improvements in the Physical and Mental Components Summary scores of the 36-Item Short-Form Health Survey were significantly improved at 6 months, compared with baseline. The strength of findings was limited by the small sample size and short follow-up; without full enrollment of 250 patients, the trial is underpowered to detect contributing factors to fusion and pain relief. Also, the trial does not have a control group.

Fuchs and Ruhl (2018) published 2-year results of a prospective multi-center cohort of the posterior approach to arthrodesis of the SIJ.43 A total of 171 patients from 20 hospitals in Germany were treated from 2011 to 2012 using a DIANA implant (marketed in the U.S. as the NADIA implant). The DIANA implant is a hollow, tapered dowel that comes in diameters of 13, 15, 17, or 19 mm. A distraction tool was used to determine the size of the implant, which is inserted between the ilium and sacrum under distraction. Allogeneic bone grafts were used in 66% of cases. Patients had partial weight bearing on the operated side for 6 to 8 weeks. At the 2 year follow-up, VAS had decreased from 74 to 37, ODI improved from 51% to 33%, and the McGill Pain Questionnaire decreased from 50% to 31% (all p < .001). Use of opioids decreased from 49.3% of patients to 30.3% at follow-up. In computed tomography (CT) scans, only 31% of patients showed SIJ fusion at 2 years.

Table 18. Pain and Disability Scores After Implantation With a Cylindrical Threaded Implant

Outcome Measures Baseline 3 Months (SD) 6 Months (SD) 12 Months (SD) 24 Months (SD) p
Low back pain 55.8 (26.7) 28.5 (21.6) 31.6 (26.9) 32.7 (27.4) 20.0 (18.4) < .01
Left leg pain 40.6 (29.5) 19.5 (22.9) 16.4 (25.6) 12.5 (23.3) 5.8 (8.1) < .01
Right leg pain 40.0 (34.1) 18.1 (26.3) 20.6 (25.4) 14.4 (21.1) 11.5 (20.1) < .05
Oswestry Disability Index 55.6 (16.1) 33.3 (16.8) 33.0 (16.8) 34.6 (19.4) 27.5 (18.8) < .01

Adapted from Rappoport et al.40,41
SD: standard deviation.

Section Summary: SIJ Fixation/Fusion With an Implant Other Than a Transiliac Triangular Implant
The evidence on the fusion of the SIJ with devices other than the triangular implant includes 3 prospective cohort studies; 2 were conducted with transiliac screws, and the third with a posterior approach. No controlled studies were identified. Meta-analyses of the available prospective and retrospective studies indicate improvement in subjective outcomes from before surgery to follow-up in these unblinded studies. The meta-analyses comparing outcomes from these cohorts with non-concurrent studies suggest a possible difference in outcomes between the more well-studied triangular transiliac implant and other implant designs and approaches. There is uncertainty in the health benefit of SIJ fusion/fixation with these various implant designs. Controlled studies with the different implant designs and approaches are needed to evaluate these devices.

Summary of Evidence
Diagnostic

For individuals who have suspected SIJ pain who receive a diagnostic sacroiliac block, the evidence includes systematic reviews. Relevant outcomes are test validity, symptoms, functional outcomes, QOL, medication use, and treatment-related morbidity. Current evidence is conflicting on the diagnostic utility of SIJ blocks. The evidence is insufficient to determine that the technology results in an improvement in the net health outcome.

Therapeutic
For individuals who have SIJ pain who receive therapeutic corticosteroid injections, the evidence includes systematic reviews, small RCTs, and case series. Relevant outcomes are symptoms, functional outcomes, QOL, medication use, and treatment-related morbidity. In general, the literature on injection therapy of joints in the back is of poor quality. Results from 2 small RCTs showed that therapeutic SIJ steroid injections were not as effective as other active treatments. Larger trials, preferably using sham injections, are needed to determine the degree of benefit of corticosteroid injections over placebo. The evidence is insufficient to determine that the technology results in an improvement in the net health outcome.

For individuals who have SIJ pain who receive RFA, the evidence includes 5 RCTs using different radiofrequency applications and case series. Relevant outcomes are symptoms, functional outcomes, QOL, medication use, and treatment-related morbidity. Meta-analysis of available sham-controlled RCTs suggests that there may be a small effect of RFA on SIJ pain at short-term (1 to 3 months) follow-up. However, the RCTs of RFA have methodologic limitations, and there is limited data on the duration of the treatment effect. The single RCT with 6 and 12-month follow-up showed no significant benefit of RFA compared to an exercise control group at these time points. In addition, heterogeneity of RFA treatment techniques precludes generalizing results across different studies. For RFA with a cooled probe, 2 small RCTs reported short-term benefits, but these are insufficient to determine the overall effect on health outcomes. An RCT on palisade RFA of the SIJ did not include a sham control. Another sham-controlled RCT showed no benefit from RFA. Further high-quality controlled trials are needed to compare this procedure in defined populations with sham control and alternative treatments. The evidence is insufficient to determine that the technology results in an improvement in the net health outcome.

For individuals who have SIJ pain who receive SIJ fixation/fusion with a transiliac triangular implant, the evidence includes 2 nonblinded RCTs of minimally invasive fusion, prospective cohorts with more than 85% follow-up, and case series. Relevant outcomes are symptoms, functional outcomes, QOL, medication use, and treatment-related morbidity. Both RCTs have reported outcomes past 6 months, after which crossover was allowed. Both studies reported significantly greater reductions in VAS pain scores and ODI scores in SIJ fusion patients than in control groups. The reductions in pain and disability observed in the SIJ fusion group at 6 months were maintained out to 1 year compared with controls who had not crossed over. The RCTs were nonblinded without a placebo or an active control group. Prospective cohorts and case series with sample sizes ranging from 45 to 149 patients and low dropout rates (< 15%) also showed reductions in pain and disability out to 5 years. The cohort studies and case series are consistent with the durability of treatment benefit. The evidence is sufficient to determine that the technology results in an improvement in the net health outcome.

For individuals who have SIJ pain who receive SIJ fusion/fixation with an implant other than a transiliac triangular implant, the evidence includes 3 prospective cohort studies and retrospective case series. Relevant outcomes are symptoms, functional outcomes, QOL, medication use, and treatment-related morbidity. Two prospective cohorts were conducted with transiliac screws and the third with a device inserted through a posterior approach. No controlled studies were identified. Meta-analyses of the available prospective and retrospective studies indicate improvement in subjective outcomes from before surgery to follow-up, but with a possible difference in outcomes between the more well studied triangular transiliac implant and other implant designs and approaches. There is uncertainty in the health benefit of SIJ fusion/fixation with these implant designs. Therefore, controlled studies with a larger number of patients and longer follow-up are needed to evaluate these devices. The evidence is insufficient to determine that the technology results in an improvement in the net health outcome.

The purpose of the following information is to provide reference material. Inclusion does not imply endorsement or alignment with the evidence review conclusions.

Clinical Input From Physician Specialty Societies and Academic Medical Centers
While the various physician specialty societies and academic medical centers may collaborate with and make recommendations during this process, through the provision of appropriate reviewers, input received does not represent an endorsement or position statement by the physician specialty societies or academic medical centers, unless otherwise noted.

2017 Input
Clinical input was sought to help determine whether the use of sacroiliac joint (SIJ) fusion for individuals with SIJ pain would provide a clinically meaningful improvement in net health outcome and whether the use is consistent with generally accepted medical practice. In response to requests, clinical input was received from 10 respondents, including 5 specialty society-level responses from 7 specialty societies (2 were joint society responses) and 5 physician-level responses from 4 academic centers while this policy was under review in 2017.

For carefully selected patients as outlined in statements from the North American Spine Society who have SIJ pain who receive percutaneous and minimally invasive techniques of SIJ fusion, the clinical input supports this use provides a clinically meaningful improvement in the net health outcome and is consistent with generally accepted medical practice.

Further details from clinical input are included in the appendix.

2014 Input
In response to requests, input was received from 4 physician specialty societies and 4 academic medical centers (5 responses) while this policy was under review in 2014. Input was mixed on the use of arthrography, radiofrequency ablation, and fusion of the SIJ. Most reviewers considered injection for diagnostic purposes to be medically necessary when using controlled blocks with at least 75% pain relief, and for injection of corticosteroids for treatment purposes. Treatment with prolotherapy, periarticular corticosteroid, and periarticular botulinum toxin were considered investigational by most reviewers.

2010 Input
In response to requests, input was received from 4 physician specialty societies (6 responses) and 3 academic medical centers (5 responses) while this policy was under review in 2010. Input was mixed. There was general agreement that the evidence for SIJ injections is limited, although most reviewers considered sacroiliac injections to be the best available approach for diagnosis and treatment in defined situations.

Practice Guidelines and Position Statements
Guidelines or position statements will be considered for inclusion in Supplemental Information if they were issued by, or jointly by, a U.S. professional society, an international society with U.S. representation, or National Institute for Health and Care Excellence (NICE). Priority will be given to guidelines that are informed by a systematic review, include strength of evidence ratings, and include a description of management of conflict of interest.

North American Spine Society
The North American Spine Society (NASS) has developed appropriate use criteria for percutaneous SIJ fusion, SIJ injection, and radiofrequency ablation. These criteria can be accessed by payers through a registration process. For further information, see https://www.spine.org/Research-Clinical-Care/Quality-Improvement/Clinical-Guidelines.

American Society of Interventional Pain Physicians
In 2013, the American Society of Interventional Pain Physicians guideline recommended the use of controlled SIJ blocks with placebo or controlled comparative local anesthetic block when indications are satisfied with suspicion of SIJ pain.4 A positive response to a joint block is considered to be at least a 75% improvement in pain or in the ability to perform previously painful movements. For therapeutic interventions, the only effective modality with fair evidence was cooled radiofrequency neurotomy, when used after the appropriate diagnosis was confirmed by diagnostic SIJ injections.

American Society of Anesthesiologists & American Society of Regional Anesthesia and Pain Medicine
The American Society of Anesthesiologists and the American Society of Regional Anesthesia and Pain Medicine have a 2010 guideline for chronic pain management.44 The guideline recommends that “Diagnostic sacroiliac joint injections or lateral branch blocks may be considered for the evaluation of patients with suspected sacroiliac joint pain.” Based on the opinions of consultants and society members, the guideline recommends that “Water-cooled radiofrequency ablation may be used for chronic sacroiliac joint pain.”

International Society for the Advancement of Spine Surgery
In 2020, the International Society for the Advancement of Spine Surgery provided guidance on indications for minimally invasive SIJ fusion with placement of lateral transfixing devices.39

The society recommended that "patients who have all of the following criteria may be eligible for lateral MIS [minimally invasive surgical] SIJF with placement of lateral transfixing devices:"

  • "Chronic SIJ pain (pain lasting at least 6 months)
  • Significant SIJ pain that impacts QOL [quality of life] or significantly limits activities of daily living
  • SIJ pain confirmed with at least 3 physical examination maneuvers that stress the SIJ [list provided above] and reproduce the patient’s typical pain
  • Confirmation of the SIJ as a pain generator with > 50% acute decrease in pain upon fluoroscopically guided diagnostic intra-articular SIJ block using a small volume (< 2.5 mL) of local anesthetic.
  • Failure to respond to nonsurgical treatment consisting of NSAIDs [nonsteroidal anti-inflammatory drugs] and a reasonable course (4 to 6 weeks) of PT [physical therapy]. Failure to respond means continued pain that interferes with activities of daily living and/or results in functional disability"

It was recommended that intra-articular SIJ steroid injection and radiofrequency ablation (RFA) of the SIJ lateral branch nerves may be considered but are not required.

Specifically not recommended were:

  • Minimally invasive posterior (dorsal) SIJ fusion.
  • Repeat intra-articular steroid injection.
  • Repeat SIJ radiofrequency ablation.

American Society of Pain and Neuroscience
In 2021, the American Society of Pain and Neuroscience published practice a guideline on radiofrequency neurotomy.45 All of the workgroup members utilized radiofrequency neurotomy in clinical practice. A consensus statement, based on Grade II-1 evidence (well-designed, controlled, nonrandomized clinical trial), was that "lateral branch radiofrequency neurotomy may be used for the treatment of posterior sacral ligament and joint pain following positive response to appropriately placed diagnostic blocks."

National Institute for Health and Care Excellence
In 2017, the National Institute for Health and Care Excellence guidance on minimally invasive SIJ fusion surgery for chronic sacroiliac pain included the following recommendations:

1.1 "Current evidence on the safety and efficacy of minimally invasive sacroiliac (SI) joint fusion surgery for chronic SI pain is adequate to support the use of this procedure.

1.2 Patients having this procedure should have a confirmed diagnosis of unilateral or bilateral SI joint dysfunction due to degenerative sacroiliitis or SI joint disruption.

1.3 This technically challenging procedure should only be done by surgeons who regularly use image-guided surgery for implant placement. The surgeons should also have had specific training and expertise in minimally invasive SI joint fusion surgery for chronic SI pain.”46

U.S. Preventive Services Task Force Recommendations
Not applicable

Ongoing and Unpublished Clinical Trials
Some currently ongoing and unpublished trials that might influence this policy are listed in Table 19.

Table 19. Summary of Key Trials

NCT No. Trial Name Planned Enrollment Completion Date
Ongoing      
NCT04423120a A Single Arm, Multicenter, Prospective, Clinical Study on a Novel Minimally Invasive Posterior Sacroiliac Fusion Device 100 Mar 2026
NCT04218838a A Prospective, Multi-Center, Bi-Phasic Randomized Design to Compare Outcomes of the CornerLoc™ SI Joint Stabilization System and Intra-Articular Sacroiliac Joint Steroid Injection in Patients With Refractory Sacroiliac Joint Dysfunction 120 Jul 2023
NCT03601949a A Prospective, Multi-Center, Randomized, Assessor Blind, Controlled Study Comparing Lateral Branch Cooled Radiofrequency Denervation to Conservative Therapy as Treatment for Sacroiliac Joint Pain in a Military and Civilian Population 210 Jul 2022
NCT04062630a Sacroiliac Joint Stabilization in Long Fusion to the Pelvis: Randomized Controlled Trial (SILVIA) 213 Dec 2024
NCT03507049 Sacroiliac Joint Fusion Versus Sham Operation for Treatment of Sacroiliac Joint Pain. A Prospective Double Blinded Randomized Controlled Multicenter Trial. 63 May 2030
Unpublished      
NCT01861899a Treatment of Sacroiliac Dysfunction With SI-LOK® Sacroiliac Joint Fixation System 46 Apr 2019
NCT02074761a Evolusion Study Using the Zyga SImmetry Sacroiliac Joint Fusion System 250 Nov 2020

NCT: national clinical trial.
a Denotes industry-sponsored or cosponsored trial.

References

  1. Himstead AS, Brown NJ, Shahrestani S, et al. Trends in Diagnosis and Treatment of Sacroiliac Joint Pathology Over the Past 10 Years: Review of Scientific Evidence for New Devices for Sacroiliac Joint Fusion. Cureus. Jun 2021; 13(6): e15415. PMID 34249562
  2. Dreyfuss P, Michaelsen M, Pauza K, et al. The value of medical history and physical examination in diagnosing sacroiliac joint pain. Spine (Phila Pa 1976). Nov 15 1996; 21(22): 2594-602. PMID 8961447
  3. Simopoulos TT, Manchikanti L, Gupta S, et al. Systematic Review of the Diagnostic Accuracy and Therapeutic Effectiveness of Sacroiliac Joint Interventions. Pain Physician. Sep-Oct 2015; 18(5): E713-56. PMID 26431129
  4. Manchikanti L, Abdi S, Atluri S, et al. An update of comprehensive evidence-based guidelines for interventional techniques in chronic spinal pain. Part II: guidance and recommendations. Pain Physician. Apr 2013; 16(2 Suppl): S49-283. PMID 23615883
  5. Manchikanti L, Datta S, Derby R, et al. A critical review of the American Pain Society clinical practice guidelines for interventional techniques: part 1. Diagnostic interventions. Pain Physician. May-Jun 2010; 13(3): E141-74. PMID 20495596
  6. Manchikanti L, Datta S, Gupta S, et al. A critical review of the American Pain Society clinical practice guidelines for interventional techniques: part 2. Therapeutic interventions. Pain Physician. Jul-Aug 2010; 13(4): E215-64. PMID 20648212
  7. Rupert MP, Lee M, Manchikanti L, et al. Evaluation of sacroiliac joint interventions: a systematic appraisal of the literature. Pain Physician. Mar-Apr 2009; 12(2): 399-418. PMID 19305487
  8. Chou R, Atlas SJ, Stanos SP, et al. Nonsurgical interventional therapies for low back pain: a review of the evidence for an American Pain Society clinical practice guideline. Spine (Phila Pa 1976). May 01 2009; 34(10): 1078-93. PMID 19363456
  9. Chou R, Loeser JD, Owens DK, et al. Interventional therapies, surgery, and interdisciplinary rehabilitation for low back pain: an evidence-based clinical practice guideline from the American Pain Society. Spine (Phila Pa 1976). May 01 2009; 34(10): 1066-77. PMID 19363457
  10. Hansen H, Manchikanti L, Simopoulos TT, et al. A systematic evaluation of the therapeutic effectiveness of sacroiliac joint interventions. Pain Physician. May-Jun 2012; 15(3): E247-78. PMID 22622913
  11. Visser LH, Woudenberg NP, de Bont J, et al. Treatment of the sacroiliac joint in patients with leg pain: a randomized-controlled trial. Eur Spine J. Oct 2013; 22(10): 2310-7. PMID 23720124
  12. Kim WM, Lee HG, Jeong CW, et al. A randomized controlled trial of intra-articular prolotherapy versus steroid injection for sacroiliac joint pain. J Altern Complement Med. Dec 2010; 16(12): 1285-90. PMID 21138388
  13. Kennedy DJ, Engel A, Kreiner DS, et al. Fluoroscopically Guided Diagnostic and Therapeutic Intra-Articular Sacroiliac Joint Injections: A Systematic Review. Pain Med. Aug 2015; 16(8): 1500-18. PMID 26178855
  14. Chou R, Fu R, Dana T, Pappas M, Hart E, Mauer KM. Interventional Treatments for Acute and Chronic Pain: Systematic Review. Comparative Effectiveness Review No. 247. (Prepared by the Pacific Northwest Evidence-based Practice Center under Contract No. 75Q80120D00006.) AHRQ Publication No. 21-EHC030. Rockville, MD: Agency for Healthcare Research and Quality; September 2021. PMID: 34524764
  15. Chappell ME, Lakshman R, Trotter P, et al. Radiofrequency denervation for chronic back pain: a systematic review and meta-analysis. BMJ Open. Jul 21 2020; 10(7): e035540. PMID 32699129
  16. Juch JNS, Maas ET, Ostelo RWJG, et al. Effect of Radiofrequency Denervation on Pain Intensity Among Patients With Chronic Low Back Pain: The Mint Randomized Clinical Trials. JAMA. Jul 04 2017; 318(1): 68-81. PMID 28672319
  17. Chen CH, Weng PW, Wu LC, et al. Radiofrequency neurotomy in chronic lumbar and sacroiliac joint pain: A meta-analysis. Medicine (Baltimore). Jun 2019; 98(26): e16230. PMID 31261580
  18. Mehta V, Poply K, Husband M, et al. The Effects of Radiofrequency Neurotomy Using a Strip-Lesioning Device on Patients with Sacroiliac Joint Pain: Results from a Single-Center, Randomized, Sham-Controlled Trial. Pain Physician. Nov 2018; 21(6): 607-618. PMID 30508988
  19. van Tilburg CW, Schuurmans FA, Stronks DL, et al. Randomized Sham-controlled Double-Blind Multicenter Clinical Trial to Ascertain the Effect of Percutaneous Radiofrequency Treatment for Sacroiliac Joint Pain: Three-month Results. Clin J Pain. Nov 2016; 32(11): 921-926. PMID 26889616
  20. Zheng Y, Gu M, Shi D, et al. Tomography-guided palisade sacroiliac joint radiofrequency neurotomy versus celecoxib for ankylosing spondylitis: a open-label, randomized, and controlled trial. Rheumatol Int. Sep 2014; 34(9): 1195-202. PMID 24518967
  21. Patel N, Gross A, Brown L, et al. A randomized, placebo-controlled study to assess the efficacy of lateral branch neurotomy for chronic sacroiliac joint pain. Pain Med. Mar 2012; 13(3): 383-98. PMID 22299761
  22. Patel N. Twelve-Month Follow-Up of a Randomized Trial Assessing Cooled Radiofrequency Denervation as a Treatment for Sacroiliac Region Pain. Pain Pract. Feb 2016; 16(2): 154-67. PMID 25565322
  23. Whang P, Cher D, Polly D, et al. Sacroiliac Joint Fusion Using Triangular Titanium Implants vs. Non-Surgical Management: Six-Month Outcomes from a Prospective Randomized Controlled Trial. Int J Spine Surg. 2015; 9: 6. PMID 25785242
  24. Polly DW, Cher DJ, Wine KD, et al. Randomized Controlled Trial of Minimally Invasive Sacroiliac Joint Fusion Using Triangular Titanium Implants vs Nonsurgical Management for Sacroiliac Joint Dysfunction: 12-Month Outcomes. Neurosurgery. Nov 2015; 77(5): 674-90; discussion 690-1. PMID 26291338
  25. Polly DW, Swofford J, Whang PG, et al. Two-Year Outcomes from a Randomized Controlled Trial of Minimally Invasive Sacroiliac Joint Fusion vs. Non-Surgical Management for Sacroiliac Joint Dysfunction. Int J Spine Surg. 2016; 10: 28. PMID 27652199
  26. Darr E, Meyer SC, Whang PG, et al. Long-term prospective outcomes after minimally invasive trans-iliac sacroiliac joint fusion using triangular titanium implants. Med Devices (Auckl). 2018; 11: 113-121. PMID 29674852
  27. Sturesson B, Kools D, Pflugmacher R, et al. Six-month outcomes from a randomized controlled trial of minimally invasive SI joint fusion with triangular titanium implants vs conservative management. Eur Spine J. Mar 2017; 26(3): 708-719. PMID 27179664
  28. Dengler J, Sturesson B, Kools D, et al. Referred leg pain originating from the sacroiliac joint: 6-month outcomes from the prospective randomized controlled iMIA trial. Acta Neurochir (Wien). Nov 2016; 158(11): 2219-2224. PMID 27629371
  29. Dengler JD, Kools D, Pflugmacher R, et al. 1-Year Results of a Randomized Controlled Trial of Conservative Management vs. Minimally Invasive Surgical Treatment for Sacroiliac Joint Pain. Pain Physician. Sep 2017; 20(6): 537-550. PMID 28934785
  30. Dengler J, Kools D, Pflugmacher R, et al. Randomized Trial of Sacroiliac Joint Arthrodesis Compared with Conservative Management for Chronic Low Back Pain Attributed to the Sacroiliac Joint. J Bone Joint Surg Am. Mar 06 2019; 101(5): 400-411. PMID 30845034
  31. Duhon BS, Cher DJ, Wine KD, et al. Triangular Titanium Implants for Minimally Invasive Sacroiliac Joint Fusion: A Prospective Study. Global Spine J. May 2016; 6(3): 257-69. PMID 27099817
  32. Duhon BS, Bitan F, Lockstadt H, et al. Triangular Titanium Implants for Minimally Invasive Sacroiliac Joint Fusion: 2-Year Follow-Up from a Prospective Multicenter Trial. Int J Spine Surg. 2016; 10: 13. PMID 27162715
  33. Whang PG, Darr E, Meyer SC, et al. Long-Term Prospective Clinical And Radiographic Outcomes After Minimally Invasive Lateral Transiliac Sacroiliac Joint Fusion Using Triangular Titanium Implants. Med Devices (Auckl). 2019; 12: 411-422. PMID 31576181
  34. Patel V, Kovalsky D, Meyer SC, et al. Prospective Trial of Sacroiliac Joint Fusion Using 3D-Printed Triangular Titanium Implants. Med Devices (Auckl). 2020; 13: 173-182. PMID 32607011
  35. Vanaclocha V, Herrera JM, Saiz-Sapena N, et al. Minimally Invasive Sacroiliac Joint Fusion, Radiofrequency Denervation, and Conservative Management for Sacroiliac Joint Pain: 6-Year Comparative Case Series. Neurosurgery. Jan 01 2018; 82(1): 48-55. PMID 28431026
  36. Spain K, Holt T. Surgical Revision after Sacroiliac Joint Fixation or Fusion. Int J Spine Surg. 2017; 11: 5. PMID 28377863
  37. Schoell K, Buser Z, Jakoi A, et al. Postoperative complications in patients undergoing minimally invasive sacroiliac fusion. Spine J. Nov 2016; 16(11): 1324-1332. PMID 27349627
  38. Tran ZV, Ivashchenko A, Brooks L. Sacroiliac Joint Fusion Methodology - Minimally Invasive Compared to Screw-Type Surgeries: A Systematic Review and Meta-Analysis. Pain Physician. Jan 2019; 22(1): 29-40. PMID 30700066
  39. Lorio M, Kube R, Araghi A. International Society for the Advancement of Spine Surgery Policy 2020 Update-Minimally Invasive Surgical Sacroiliac Joint Fusion (for Chronic Sacroiliac Joint Pain): Coverage Indications, Limitations, and Medical Necessity. Int J Spine Surg. Dec 2020; 14(6): 860-895. PMID 33560247
  40. Rappoport LH, Luna IY, Joshua G. Minimally Invasive Sacroiliac Joint Fusion Using a Novel Hydroxyapatite-Coated Screw: Preliminary 1-Year Clinical and Radiographic Results of a 2-Year Prospective Study. World Neurosurg. May 2017; 101: 493-497. PMID 28216399
  41. Rappoport LH, Helsper K, Shirk T. Minimally invasive sacroiliac joint fusion using a novel hydroxyapatite-coated screw: final 2-year clinical and radiographic results. J Spine Surg. Jun 2021; 7(2): 155-161. PMID 34296027
  42. Araghi A, Woodruff R, Colle K, et al. Pain and Opioid use Outcomes Following Minimally Invasive Sacroiliac Joint Fusion with Decortication and Bone Grafting: The Evolusion Clinical Trial. Open Orthop J. 2017; 11: 1440-1448. PMID 29387289
  43. Fuchs V, Ruhl B. Distraction arthrodesis of the sacroiliac joint: 2-year results of a descriptive prospective multi-center cohort study in 171 patients. Eur Spine J. Jan 2018; 27(1): 194-204. PMID 29058134
  44. Benzon HT, Connis RT, De Leon-Casasola OA, et al. Practice guidelines for chronic pain management: an updated report by the American Society of Anesthesiologists Task Force on Chronic Pain Management and the American Society of Regional Anesthesia and Pain Medicine. Anesthesiology. Apr 2010; 112(4): 810-33. PMID 20124882
  45. Lee DW, Pritzlaff S, Jung MJ, et al. Latest Evidence-Based Application for Radiofrequency Neurotomy (LEARN): Best Practice Guidelines from the American Society of Pain and Neuroscience (ASPN). J Pain Res. 2021; 14: 2807-2831. PMID 34526815
  46. National Institute for Health and Care Excellence. Minimally invasive sacroiliac joint fusion surgery for chronic sacroiliac pain [IPG578]. 2017; https://www.nice.org.uk/guidance/ipg578. Accessed October 4, 2022.

Coding Section

Codes Number Description
CPT    
  20610 Arthrocentesis, aspiration and/or injection, major joint or bursa (e.g., shoulder, hip, knee, subacromial bursa); without ultrasound guidance
  27096 Injection procedure for sacroiliac joint, anesthetic/steroid, with image guidance (fluoroscopy or CT) including arthrography when performed
  27279 Arthrodesis, sacroiliac joint, percutaneous or minimally invasive (indirect visualization), with image guidance, includes obtaining bone graft when performed, and placement of transfixing device
  27280 Arthrodesis, open, sacroiliac joint, including obtaining bone graft, including instrumentation, when performed
  64451 Injection anesthetic agent, nerves innervating the sacroiliac joint with image guidance
  64625 Radiofrequency ablation, nerves innervating the sacroiliac joint, with image guidance (i.e., fluoroscopy or computed tomography)
  0809T (effective 04/01/2023) Arthrodesis, sacroiliac joint, percutaneous or minimally invasive (indirect visualization), with image guidance, placement of transfixing device(s) and intraarticular implant(s), including allograft or synthetic device(s)
HCPCS G0259 Injection procedure for sacroiliac joint; arthrography
  G0260 Injection procedure for sacroiliac joint; provision of anesthetic, steroid and/or other therapeutic agent, with or without arthrography
ICD-10-CM M46.1 Sacroiliitis, not elsewhere classified
  M47.898 Other spondylosis, sacral and sacrococcygeal region
  M47.899 Other spondylosis, site unspecified
  M48.08 Spinal stenosis, sacral and sacrococcygeal region
  M53.2X8 Spinal instabilities, sacral and sacrococcygeal region
  M54.18 Radiculopathy, sacral and sacrococcygeal region
  M54.30-M54.32 Sciatica; code range
  M54.40-M54.42 Lumbago with sciatica; code range
  M54.50-M54.59 Lower back pain; code range (eff 10/01/2021)
  M54.6 Pain in thoracic spine
  S33.2 Dislocation of sacroiliac and sacrococcygeal joint
  S33.6 Sprain of sacroiliac joint
ICD-10-PCS   ICD-10-PCS codes are only used for inpatient services
  3E0U33Z, 3E0U3BZ, 3E0U3JZ, 3E0U3NZ Administration, physiological systems and anatomical regions, introduction, joints, percutaneous, code by substance introduced (anti-inflammatory, anesthetic, contrast agent, analgesic)
  BR0D0ZZ Imaging, plain radiography of sacroiliac joints using high osmolar contrast
  BR0D1ZZ Imaging, plain radiography of sacroiliac joints using low osmolar contrast
  BR0DYZZ Imaging, plain radiography of sacroiliac joints using other contrast
  0S573ZZ, 0S583ZZ Surgical, lower joints, destruction, sacroiliac joints (right and left codes), no device
  0SG704Z, 0SG804Z, 0SG707Z, 0SG807Z, 0SG70JZ, 0SG80JZ, 0SG70KZ, 0SG80KZ, 0SG70ZZ, 0SG80ZZ Surgical, lower joints, fusion, open, sacroiliac joints (right and left codes) and various devices
  0SG734Z, 0SG834Z, 0SG737Z, 0SG837Z, 0SG73JZ, 0SG83JZ, 0SG73KZ, 0SG83KZ, 0SG73ZZ, 0SG83ZZ Surgical, lower joints, fusion, percutaneous, sacroiliac joints (right and left codes) and various devices
  0SG744Z, 0SG844Z, 0SG747Z, 0SG847Z, 0SG74JZ, 0SG84JZ, 0SG74KZ, 0SG84KZ, 0SG74ZZ, 0SG84ZZ Surgical, lower joints, fusion, percutaneous endoscopic, sacroiliac joints (right and left codes) and various devices
Type of Service  Medicine   
Place of Service  Outpatient   

Procedure and diagnosis codes on Medical Policy documents are included only as a general reference tool for each policy. They may not be all-inclusive.

This medical policy was developed through consideration of peer-reviewed medical literature generally recognized by the relevant medical community, U.S. FDA approval status, nationally accepted standards of medical practice and accepted standards of medical practice in this community, Blue Cross Blue Shield Association technology assessment program (TEC) and other nonaffiliated technology evaluation centers, reference to federal regulations, other plan medical policies and accredited national guidelines.

"Current Procedural Terminology © American Medical Association. All Rights Reserved" 

History From 2014 Forward     

03/13/2023 Adding CPT 0809T effective 04012023
02/02/2023 Annual review, no change to policy intent. Updating guidelines, rationale and references.

02/03/2022 

Annual review, adding policy verbiage related to transiliac placement of a titanium triangular implant. Also updating coding, description, background, rationale and references. Also updating regulatory status 

12/7/2021 

Updating policy with 2022 coding. Adding code 64628 and 64629. No other change made. 

06/01/2021

Adding archival date to related policy number 

02/10/2021 

Annual review, no change to policy intent. Updating description, rationale and references. 

02/03/2020 

Annual review, no change to policy intent. Updating rationale and references. 

02/13/2019 

Annual review, no change to policy intent. Updating description, rationale and references. 

03/13/2018 

Annual review, updating related policies, background, description, rationale and references. 

01/31/2018 

Interim review, updating title to indicate this policy relates to non surgical treatment of SI joint pain as a new policy title Sarcriliac Joint Fusion of Stabilization is being published. Removing surgical treatment from multiple areas of the policy. No change to the intent of diagnosis and non surgical treatment of SI joint pain. 

02/01/2017 

Annual review, no change to policy intent. Updating background, description, guidelines, rationale and references. 

02/15/2016 

Annual review, no change to policy intent. 

02/16/2015 

Added verbiage related to cooled RFA to guidelines. 

12/16/2014 

Updated to add: Injection of corticosteroid may be considered medically necessary for the treatment of sacroiliac joint.

02/24/2014

Annual review. Added regulatory status & related policies. Updated rationale, references and policy verbiage related to S/I fusion & stabilization. Intent unchanged.

Complementary Content
${loading}